IBM 8872 Service Guide - Page 146

Scalability, cartridge, assembly

Page 146 highlights

8. Connect the cables and power cords (see "Completing the installation" in the Installation Guide or User's Guide for cabling instructions). 9. Turn on all attached devices and the server. Scalability cartridge assembly To remove the scalability cartridge assembly, complete the following steps: Scalability cartridge assembly Retention latch 1. Read the safety information that begins on page vii and "Installation guidelines" on page 99. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables necessary to replace the device. 3. Remove the top cover and bezel (see "Top cover and bezel" on page 113). 4. Remove all fans (see "Hot-swap fan" on page 105). 5. Remove the memory cards (see "Removing and replacing a memory card" on page 108). 6. Lift the microprocessor-tray release latch, open the microprocessor-tray levers, and pull the microprocessor tray out of the server slightly (see "Removing and installing a microprocessor" on page 122). 7. Remove the power supplies and the power-supply structure (see "Power-supply structure" on page 119). 8. Move the retention latch away from the scalability cartridge assembly, grasp the blue handle, and lift the assembly out of the server, allowing the structure to pivot at the chassis rear. 9. Move the assembly away from the chassis rear as you lift the assembly from the server. 10. If you are instructed to return the scalability cartridge assembly, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. 130 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170

8.
Connect
the
cables
and
power
cords
(see
“Completing
the
installation”
in
the
Installation
Guide
or
User’s
Guide
for
cabling
instructions).
9.
Turn
on
all
attached
devices
and
the
server.
Scalability
cartridge
assembly
To
remove
the
scalability
cartridge
assembly,
complete
the
following
steps:
Retention latch
Scalability cartridge assembly
1.
Read
the
safety
information
that
begins
on
page
vii
and
“Installation
guidelines”
on
page
99.
2.
Turn
off
the
server
and
peripheral
devices,
and
disconnect
the
power
cords
and
all
external
cables
necessary
to
replace
the
device.
3.
Remove
the
top
cover
and
bezel
(see
“Top
cover
and
bezel”
on
page
113).
4.
Remove
all
fans
(see
“Hot-swap
fan”
on
page
105).
5.
Remove
the
memory
cards
(see
“Removing
and
replacing
a
memory
card”
on
page
108).
6.
Lift
the
microprocessor-tray
release
latch,
open
the
microprocessor-tray
levers,
and
pull
the
microprocessor
tray
out
of
the
server
slightly
(see
“Removing
and
installing
a
microprocessor”
on
page
122).
7.
Remove
the
power
supplies
and
the
power-supply
structure
(see
“Power-supply
structure”
on
page
119).
8.
Move
the
retention
latch
away
from
the
scalability
cartridge
assembly,
grasp
the
blue
handle,
and
lift
the
assembly
out
of
the
server,
allowing
the
structure
to
pivot
at
the
chassis
rear.
9.
Move
the
assembly
away
from
the
chassis
rear
as
you
lift
the
assembly
from
the
server.
10.
If
you
are
instructed
to
return
the
scalability
cartridge
assembly,
follow
all
packaging
instructions,
and
use
any
packaging
materials
for
shipping
that
are
supplied
to
you.
130
IBM
xSeries
460
Type
8872
and
xSeries
MXE
460
Type
8874:
Problem