diagnostic
![]() |
UPC - 000435813060
View all IBM 8872 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 8872 and Type 8874," on page 93 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 202-xxx-0nn Failed system cache test, where nn=APIC ID. APIC ID Microprocessor 1. Reseat the following components: a. (Trained service technician only) Microprocessor nn 00, 01 1 06, 07 2 10, 11 3 16, 17 4 b. Microprocessor tray 2. Replace the following components one at a time, in the order shown, restarting the server each time. a. (Trained service technician only) Microprocessor nn b. (Trained service technician only) Microprocessor tray 204-198-000 Test aborted. 1. Run the Quick Memory Test Diagnostic All Banks (see "Running the diagnostic programs" on page 59). 2. Update the BIOS code (see "Updating the firmware" on page 133). 3. Look in the test log (see "Viewing the test log" on page 60) and correct any other errors. 204-210-000 Test failed. 1. Run the Quick Memory Test Diagnostic All Banks (see "Running the diagnostic programs" on page 59). 2. Update the BIOS code (see "Updating the firmware" on page 133). 3. Look in the test log (see "Viewing the test log" on page 60) and correct any other errors. 215-xxx-000 Failed CD or DVD test. 1. Run the test again with a different CD or DVD. 2. Reseat the following components: a. CD or DVD drive b. Front panel assembly 3. Replace the following components one at a time, in the order shown, restarting the server each time: a. CD or DVD drive b. (Trained service technician only) Front panel assembly 217-xxx-000 Failed BIOS fixed disk test. Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Reseat hard disk drive 1. 2. Replace hard disk drive 1. 217-xxx-001 Failed BIOS fixed disk test. Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Reseat hard disk drive 2. 2. Replace hard disk drive 2. 217-xxx-002 Failed BIOS fixed disk test. Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Reseat hard disk drive 3. 2. Replace hard disk drive 3. Chapter 2. Diagnostics 75
![](/manual_guide/products/ibm-8872-service-guide-0d7ed5c/91.png)