IBM 8872 Service Guide - Page 72
which
![]() |
UPC - 000435813060
View all IBM 8872 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 8872 and Type 8874," on page 93 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Lit light path diagnostics LED with the system-error or system-information LED also lit Description Action FAN A fan has failed or has been 1. Reinstall the removed fan. removed. Note: A failing fan can also cause 2. If an individual fan LED is lit, replace the fan. the TEMP LED to be lit. 3. Reseat the microprocessor tray. 4. (Trained service technician only) Replace the microprocessor tray. PCI BRD The PCI-X board has failed. 1. (Trained service technician only) Reseat the PCI-X board assembly. 2. (Trained service technician only) Replace the PCI-X board assembly. CPU BRD The microprocessor tray has failed. 1. Reseat the microprocessor tray. 2. (Trained service technician only) Replace the microprocessor tray. I/O BRD The I/O board has failed. 1. Reseat the I/O board. 2. Replace the I/O board. 56 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide