IBM 8872 Service Guide - Page 92
controller
![]() |
UPC - 000435813060
View all IBM 8872 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 8872 and Type 8874," on page 93 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 217-xxx-003 Failed BIOS fixed disk test. Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Reseat hard disk drive 4. 2. Replace hard disk drive 4. 217-xxx-004 Failed BIOS fixed disk test. Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Reseat hard disk drive 5. 2. Replace hard disk drive 5. 217-xxx-005 Failed BIOS fixed disk test. Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Reseat hard disk drive 6. 2. Replace hard disk drive 6. 217-198-xxx Could not establish drive parameters. 1. Check the drive cables and terminators. 2. Reseat the hard disk drive. 3. Replace the hard disk drive. 301-xxx-000 Failed keyboard test. Note: After installing a USB keyboard, you might have to use the Configuration/Setup Utility program to enable keyboardless operation and prevent the POST error message 301 from being displayed during startup. 1. Reseat the following components: a. Keyboard b. I/O board 2. Replace the components listed in step 1 one at a time, in the order shown, restarting the server each time. 302-xxx-xxx Failed mouse test. 1. Reseat the following components: a. Mouse b. I/O board 2. Replace the components listed in step 1 one at a time, in the order shown, restarting the server each time. 305-xxx-xxx Failed video monitor test. 1. Reseat the following components: a. Monitor b. I/O board 2. Replace the components listed in step 1 one at a time, in the order shown, restarting the server each time. 405-xxx-000 Failed Ethernet test on controller on I/O board. 1. Make sure that Ethernet is not disabled in the Configuration/Setup Utility program and that the BIOS code is at the latest level. 2. Run the loopback diagnostic. 3. Reseat the I/O board. 4. Replace the I/O board. 405-xxx-00n No good link! Check loopback plug. 1. Make sure that the loopback plug is a gigabit loopback plug (see "Solving Ethernet controller problems" on page 88). 2. Check for any loose connections between the loopback plug and the Ethernet connector. 76 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide
![](/manual_guide/products/ibm-8872-service-guide-0d7ed5c/92.png)