IBM 8872 Service Guide - Page 81
actions
UPC - 000435813060
View all IBM 8872 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 8872 and Type 8874," on page 93 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 035-002-0nn ServeRAID interface timeout. 1. The ServeRAID controller might not be configured correctly. Obtain the basic and extended configuration status bytes and see the ServeRAID Hardware Maintenance Manual for more information. 2. Reseat the following components: a. SAS hard disk drive backplane cables b. ServeRAID controller 3. Replace the components listed in step 2 one at a time, in the order shown, restarting the server each time. 035-253-0nn ServeRAID controller 0nn initialization failure; 0nn = the controller number. 1. The ServeRAID controller might not be configured correctly. See the ServeRAID Hardware Maintenance Manual for more information. 2. Reseat the following components: a. SAS hard disk drive backplane cables b. ServeRAID controller 3. Replace the components listed in step 2 one at a time, in the order shown, restarting the server each time. 035-253-s99 RAID adapter initialization failure. 1. Reseat the following components: a. ServeRAID adapter b. SAS hard disk drive backplane cable 2. Replace the components listed in step 1 one at a time, in the order shown, restarting the server each time. 035-254-0nn Setup error; unable to allocate memory to run test. Check the system resources and make more memory available (see "Configuration/Setup Utility menu choices" on page 135); then, run the test again. 035-255-0nn Internal error. 1. Reseat the SAS hard disk drive backplane cable. 2. Replace the SAS hard disk drive backplane. 035-260-0nn System to controller interface failure. 1. Reseat the following components: a. ServeRAID adapter b. I/O board 2. Replace the components listed in step 1 one at a time, in the order shown, restarting the server each time. 035-265-0nn Adapter Communication error. 1. Update the RAID controller firmware (see "Updating the firmware" on page 133). 2. Reseat the RAID controller. 3. Replace the RAID controller. Chapter 2. Diagnostics 65