2 INSTALLATION AND CONNECTIONS Selecting a location Select a location for the receiver that allows adequate air circulation, free from extreme heat, cold or vibrations, and other electromagnetic sources. An improper location may damage the receiver. Never place the receiver in areas such as: • Temperatures below -10°C (+40°F) or above +60°C (+140°F). • Unstable place slope or vibrate. • In direct sunlight. • High humidity and temperature. • Dusty environments. • Noisy environments. Heat dissipation ••DO NOT place the receiver against walls, or put anything on top of the receiver. This may block airflow. ••NEVER install the receiver in a place without adequate ventilation. Heat dissipation may be reduced, and the receiver may be damaged. For desktop use The receiver has a stand for desktop use. zzPull the stand until it locks in place. Grounding To prevent electrical shock, interfere from other electric devices and other problems, ground the receiver using the ground terminal [GND] on the rear panel. For best results, connect a heavy gauge wire or strap to a long ground rod. Make the distance between the [GND] terminal and ground as short as possible. RWARNING! NEVER connect the [GND] terminal to a gas or electric pipe, since the connection could cause an explosion or electric shock. Connecting a DC power supply DDPower supply You can use any of the power sources listed below. ••13.8 V DC power supply (User supplied) ••Optional SP-39AD (External speaker with built-in power supply) ••Optional AD-55NS (Power adapter) External power supply (User supplied) _+ AC outlet When disconnecting, firmly push down the locking tab and then pull the connector out of the socket. Black Red IC-R8600 Supplied DC power cable Stand CAUTION: NEVER carry the receiver by holding the stand, dials, controls and so on. This may damage them. SP-39AD (Option) AC outlet Short connector: Connect when Speaker cable SP-39AD or AD-55NS is used. AC outlet AD-55NS (Option) DC power cable DDTurning the receiver's power ON or OFF zzPush to turn ON the power. zzHold down until the "POWER OFF..." is displayed. 2-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

2
2-1
INSTALLATION AND CONNECTIONS
Selecting a location
For desktop use
Select a location for the receiver that allows adequate
air circulation, free from extreme heat, cold or
vibrations, and other electromagnetic sources.
An improper location may damage the receiver.
Never place the receiver in areas such as:
• Temperatures below –10°C (+40°F) or above +60°C
(+140°F).
• Unstable place slope or vibrate.
• In direct sunlight.
• High humidity and temperature.
• Dusty environments.
• Noisy environments.
D
Power supply
You can use any of the power sources listed below.
• 13.8 V DC power supply (User supplied)
• Optional SP-39AD
(External speaker with built-in power supply)
• Optional AD-55NS (Power adapter)
D
Turning the receiver's power ON or OFF
z
Push
to turn ON the power.
z
Hold down
until the "POWER OFF..." is
displayed.
The receiver has a stand for desktop use.
z
Pull the stand until it locks in place.
CAUTION: NEVER
carry the receiver by holding the stand,
dials, controls and so on. This may damage them.
Heat dissipation
Grounding
To prevent electrical shock, interfere
from other electric devices and other
problems, ground the receiver using
the ground terminal [GND] on the rear
panel.
For best results, connect a heavy
gauge wire or strap to a long ground
rod. Make the distance between the
[GND] terminal and ground as short as
possible.
R
WARNING! NEVER
connect the [GND] terminal
to a gas or electric pipe, since the connection could
cause an explosion or electric shock.
DO NOT
place the receiver against walls, or put
anything on top of the receiver. This may block airflow.
NEVER
install the receiver in a place without
adequate ventilation. Heat dissipation may be
reduced, and the receiver may be damaged.
Stand
Connecting a DC power supply
+
_
IC-R8600
AC outlet
When disconnecting,
firmly push down the
locking tab and then pull
the connector out of the
socket.
AC outlet
Short connector:
Connect when
SP-39AD or
AD-55NS is used.
AC outlet
DC power cable
AD-55NS (Option)
SP-39AD
(Option)
Speaker
cable
Supplied DC power cable
Red
External power supply
(User supplied)