Icom IC-R8600 Instruction Manual - Page 74

Network, Default Gateway Valid after Restart

Page 74 highlights

11 SET MODE Connectors (Continued) CI-V > CI-V USB (Rear) Port  (Default: Unlink from [REMOTE]) Selects the internal connection type between the [USB] port on the rear panel and the [REMOTE] CI-V port. ••Link to [REMOTE]: The [USB] port on the rear panel and the [REMOTE] CI-V port are internally connected. ••Unlink from [REMOTE]: The [USB] port on the rear panel and [REMOTE] CI-V port are not internally connected. Each port functions independently. (duplex communication can be made.) CI-V > CI-V USB (Rear) Baud Rate (Default: Auto) Selects the CI-V data transfer rate (bps) for [USB] on the rear panel. ••Options: 4800, 9600, 19200, 38400, 57600, 115200 or Auto LWhen "Auto" is selected, the baud rate is automatically set according to the data rate of the connected controller. LThis setting is valid only when the "CI-V USB Port" item is set to "Unlink from [REMOTE]." CI-V > CI-V USB (Rear) Echo Back (Default: OFF) Turns the Data Echo Back function ON or OFF, when remotely controlling through the [USB] CI-V port. ••OFF: Turns OFF the function. ••ON: Turns ON the function. LThis setting is .valid only when the "CI-V USB Port" item is set to "Unlink from [REMOTE]." External Meter Output (Default: Signal) Selects the signal output from [METER]. ••Signal: Signal strength. ••Signal+SQL: Signal strength and squelch level. External Meter Level (Default: 50%) Sets the voltage level output from [METER]. ••Range: 0 ~ 100% L8 V DC is output at full scale (50%). (into a 10 kΩ load) REF IN/OUT (Default: OFF) Selects the receiver's reference frequency signal source. • IN: Uses an external reference signal.  NOTE: SELECT "OFF" or "OUT" if you are not use a reliable external signal source. When the input signal source level is too low, or the frequency precision is not high, the frequency readout blinks and the receiver does not function correctly. • OFF: Does not input/output the reference signal. • OUT: Outputs the internal reference signal. Network MENU » SET > Network DHCP (Valid after Restart) (Default: ON) Turns the DHCP function ON or OFF. • OFF: Uses the static IP address. • ON: Uses the DHCP function. If a DHCP server is in your network environ- ment, the IP address is automatically obtained. LThis setting takes effect after restart. IP Address (Valid after Restart)  (Default: 192.168. 0. 10) Sets the static IP address. LThis setting is valid when "OFF" is selected the [DHCP (Valid after Restart)] item. LThis setting takes effect after restart. Subnet Mask (Valid after Restart)  (Default: 255.255.255.0 (24bit)) Sets the subnet mask to connect to your PC or LAN (Local Area Network), through the Ethernet. Rotate to set. ••Range: 128.0.0.0 (1 bit) ~ 255.255.255.252 (30 bit) LThis setting takes effect after restart. Default Gateway (Valid after Restart)  (Default: . . . ) When you remotely control the IC-R8600 using the op- tional RS-R8600, a default gateway setting is required. LThis setting is valid when "OFF" is selected the [DHCP (Valid after Restart)] item. LThis setting takes effect after restart. Primary DNS Server (Valid after Restart)  (Default: . . . ) If there are two DNS server addresses, enter the primary DNS server address. LThis setting takes effect after restart. 2nd DNS Server (Valid after Restart)  (Default: . . . ) If there are two DNS server addresses, enter the secondary DNS server address. LThis setting takes effect after restart. 11-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

11
SET MODE
11-7
Connectors (Continued)
CI-V >
CI-V USB (Re±r) Port
(Default: Unlink from [REMOTE])
Selects the internal connection type between the [USB]
port on the rear panel and the [REMOTE] CI-V port.
• Link to [REMOTE]:
The [USB] port on the rear panel and the
[REMOTE] CI-V port are internally connected.
• Unlink from [REMOTE]:
The [USB] port on the rear panel and [REMOTE]
CI-V port are not internally connected.
Each port functions independently.
(duplex communication can be made.)
CI-V >
CI-V USB (Re±r) B±ud R±te
(Default: Auto)
Selects the CI-V data transfer rate (bps) for [USB] on
the rear panel.
• Options:
4800, 9600, 19200, 38400, 57600, 115200 or Auto
L
When “Auto” is selected, the baud rate is automatically set
according to the data rate of the connected controller.
L
This setting is valid only when the “CI-V USB Port” item is
set to “Unlink from [REMOTE].”
CI-V >
CI-V USB (Re±r) Echo B±ck
(Default: OFF)
Turns the Data Echo Back function ON or OFF, when
remotely controlling through the [USB] CI-V port.
OFF: Turns OFF the function.
• ON:
Turns ON the function.
L
This setting is .valid only when the “CI-V USB Port” item is
set to “Unlink from [REMOTE].”
Extern±l Meter Output
(Default: Signal)
Selects the signal output from [METER].
• Signal:
Signal strength.
Signal+SQL:
Signal strength and squelch level.
Extern±l Meter Level
(Default: 50%)
Sets the voltage level output from [METER].
Range: 0 ~ 100%
L
8 V DC is output at full scale (50%). (into a 10 kΩ load)
REF I²/OUT
(Default: OFF)
Selects the receiver’s reference frequency signal source.
• IN:
Uses an external reference signal.
NOTE: SELECT “OFF” or “OUT”
if you are
not use a reliable external signal source.
When the input signal source level is too low,
or the frequency precision is not high, the fre-
quency readout blinks and the receiver does
not function correctly.
• OFF:
Does not input/output the reference signal.
• OUT:
Outputs the internal reference signal.
²etwork
DHCP (Valid after Restart)
(Default: ON)
Turns the DHCP function ON or OFF.
• OFF: Uses the static IP address.
• ON:
Uses the DHCP function.
If a DHCP server is in your network environ-
ment, the IP address is automatically obtained.
L
This setting takes effect after restart.
IP Address (Valid after Restart)
(Default: 192.168. 0. 10)
Sets the static IP address.
L
This setting is valid when “OFF” is selected the [DHCP
(Valid after Restart)] item.
L
This setting takes effect after restart.
Subnet Mask (Valid after Restart)
(Default: 255.255.255.0 (24bit))
Sets the subnet mask to connect to your PC or LAN
(Local Area Network), through the Ethernet. Rotate
to set.
Range: 128.0.0.0 (1 bit) ~ 255.255.255.252 (30 bit)
L
This setting takes effect after restart.
Default Gateway (Valid after Restart)
(Default:
.
.
.
)
When you remotely control the IC-R8600 using the op-
tional RS-R8600, a default gateway setting is required.
L
This setting is valid when “OFF” is selected the [DHCP
(Valid after Restart)] item.
L
This setting takes effect after restart.
Primary DNS
Server (Valid after Restart)
(Default:
.
.
.
)
If there are two DNS server addresses, enter the pri-
mary DNS server address.
L
This setting takes effect after restart.
2nd DNS
Server (Valid after Restart)
(Default:
.
.
.
)
If there are two DNS server addresses, enter the sec-
ondary DNS server address.
L
This setting takes effect after restart.
MENU
»
SET >
²etwork