Icom IC-R8600 Instruction Manual - Page 55
Setting the Scan Resume function, Setting the scan pause timer, Setting the resume delay timer
View all Icom IC-R8600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
SCANS 9 Setting the Scan Resume function DDSetting the scan pause timer You can set the delay time for when the scan resumes. zzRotate to set the pause time. LThe settable values are displayed while rotating the dial. ••1s ~ 30s: The scan pauses for the set pause time, then resumes. (Even while still receiving a signal.) ••HOLD: The scan pauses until the signal disappears, then resumes after the preset delay time has expired. DDSetting the resume delay timer You can set the delay time for when the scan resumes after the signal disappears. 1. Push . 2. Touch "RESUME TIME." 3. Rotate to set the delay time. ••0s ~ 5s: The scan resumes after the preset delay time. ••HOLD: The scan remains paused according to the Pause Timer, even if the signal disappears. • Rotate to resume the scan. • When PAUSE TIME is set to between 1 and 30 seconds, the scan resumes according to the PAUSE TIME setting. DDSetting the Scan Resume condition You can set the Scan Resume options for when a signal is received. 1. Hold down for 1 second. 2. Touch a resume option. ••[OFF]: When a signal is received, the scan is canceled. ••[ON]: When a signal is received, the scan pauses for the preset pause time, then resumes. (Set the pause time in PAUSE TIME and RESUME TIME.) Setting the priority interval Priority scan checks the priority channel according to the set interval. 1. Push . 2. Touch [PRIO INTVL]. Priority scan (Example) 1 90.6 MHz (VFO) 145 MHz (Memory channel) 2 A priority scan periodically checks a selected memory channel* while receiving on a VFO frequency. 3 *Memory channel, Auto Memory Write channel, Scan Skip Channel or Program Scan Edge Channel. 4 DDPriority scan operation 5 1. Open the SCAN screen. MENU » SCAN 6 2. Touch [TYPE/SET]. 7 8 SCAN screen 9 3. Touch [PRIO]. 10 11 4. Touch [SELECT] to select the item to change. ••No.: Priority memory preset number (0 ~ 9) (You can save up to 10 pairs of Group and Ch.) ••Group: Memory Group number ••Ch: Memory channel number. 12 13 14 15 5. Rotate to change the setting. 16 LYou cannot select blank channels. 6. Touch [SELECT] several times to exit the edit 17 mode, then touch [START] or push . ••A Priority scan starts. 18 Blinks 19 ••To cancel the scan, push or touch [STOP]. 20 7. To close the SCAN screen, push . 21 DDMonitoring the Priority channel zzDuring a Priority scan, hold down for 1 second to monitor the priority channel. ••"PRIO" is displayed while monitoring. ••Push to cancel the monitoring. 3. Rotate . ••Setting range: 1 ~ 15 seconds 9-2