Icom IC-R8600 Instruction Manual - Page 26
Setting the span, SCOPE OPERATION, SCOPE
View all Icom IC-R8600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
4 SCOPE OPERATION Spectrum scope screen (Continue) DDSetting the span Set the frequency range around the receive frequency. Settable span: ±2.5, 5.0, 10, 25, 50, 100, 250, 500 kHz, 1.0 and 2.5 MHz. 1. Open the SPECTRUM SCOPE screen. MENU » SCOPE 2. Touch [CENT/FIX] to select the Center mode. ••E ach touch changes between the Center and Fixed mode. 3. Touch [SPAN]. DDSetting the range The signals within a specified frequency range are displayed. Settable range: 0.010 ~ 3000.000 MHz. 1. Open the SPECTRUM SCOPE screen. MENU » SCOPE 2. Touch [CENT/FIX]. ••E ach touch changes between the Center and Fixed mode. 3. Touch [EDGE]. 4. Touch [-] or The span range changes. 5. T o exit the SPECTRUM SCOPE screen, push several times. 4. Touch [EDIT]. 5. Touch [] to select the upper or lower edge. ••The selected frequency edge is highlighted. 6. Touch the numeric keys, or rotate to change the frequency, then touch [ENT]. L When the operating frequency moves outside the upper or lower Edge frequency, "" is displayed in the upper side corners of the SPECTRUM SCOPE screen. ">>" blinks when the frequency is outside the higher edge (Example: 94.600). "