Icom IC-R8600 Instruction Manual - Page 26

Setting the span, SCOPE OPERATION, SCOPE

Page 26 highlights

4 SCOPE OPERATION Spectrum scope screen (Continue) DDSetting the span Set the frequency range around the receive frequency. Settable span: ±2.5, 5.0, 10, 25, 50, 100, 250, 500 kHz, 1.0 and 2.5 MHz. 1. Open the SPECTRUM SCOPE screen. MENU » SCOPE 2. Touch [CENT/FIX] to select the Center mode. ••E ach touch changes between the Center and Fixed mode. 3. Touch [SPAN]. DDSetting the range The signals within a specified frequency range are displayed. Settable range: 0.010 ~ 3000.000 MHz. 1. Open the SPECTRUM SCOPE screen. MENU » SCOPE 2. Touch [CENT/FIX]. ••E ach touch changes between the Center and Fixed mode. 3. Touch [EDGE]. 4. Touch [-] or The span range changes. 5. T o exit the SPECTRUM SCOPE screen, push several times. 4. Touch [EDIT]. 5. Touch [] to select the upper or lower edge. ••The selected frequency edge is highlighted. 6. Touch the numeric keys, or rotate to change the frequency, then touch [ENT]. L When the operating frequency moves outside the upper or lower Edge frequency, "" is displayed in the upper side corners of the SPECTRUM SCOPE screen. ">>" blinks when the frequency is outside the higher edge (Example: 94.600). "

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

4
SCOPE OPERATION
4-2
Spectrum scope screen (Continue)
D
Setting the span
Set the frequency range around the receive frequency.
Settable span:
±2.5, 5.0, 10, 25, 50, 100, 250, 500 kHz, 1.0 and 2.5 MHz.
1.
Open the SPECTRUM SCOPE screen.
MENU
»
SCOPE
2.
Touch [CENT/FIX] to select the Center mode.
Each touch changes between the Center and Fixed mode.
3. Touch [SPAN].
4. Touch [–] or [+].
• The span range changes.
5.
To exit the SPECTRUM SCOPE screen, push
several times.
D
Setting the range
The signals within a specified frequency range are
displayed.
Settable range:
0.010 ~ 3000.000 MHz.
1.
Open the SPECTRUM SCOPE screen.
MENU
»
SCOPE
2. Touch [CENT/FIX].
Each touch changes between the Center and Fixed mode.
3. Touch [EDGE].
4. Touch [EDIT].
5. Touch [

] to select the upper or lower edge.
• The selected frequency edge is highlighted.
6.
Touch the numeric keys, or rotate
to
change the frequency, then touch [ENT].
L
When the operating frequency moves outside
the upper or lower Edge frequency, “<<” or “>>”
is displayed in the upper side corners of the
SPECTRUM SCOPE screen.
7.
To exit the SPECTRUM SCOPE screen, push
several times.
"<<" blinks when the frequency is outside
the lower edge (Example: 92.600).
">>" blinks when the frequency is outside
the higher edge (Example: 94.600).
When the frequency goes further away,
“Scope Out of Range” is displayed.