Icom IC-R8600 Instruction Manual - Page 76

Display, MN-Q Popup MN OFF→ON

Page 76 highlights

11 SET MODE Display MENU » SET > Display LCD Backlight Sets the LCD backlight brightness. ••Range: 0 (dark) ~ 100% (bright) LED Bright Sets the LED brightness. ••Range: 0 (dark) ~ 100% (bright) Display Type (Default: 50%) (Default: 80%) (Default: A) RX Popup (Default: Normal) Selects whether or not to display the information included in the received digital signal such as call sign, caller's ID, code and so on, when you receive a digital signal. ••OFF: The information is not displayed. ••Normal: The information is displayed for approximately 3 seconds. ••RX Hold: The information is displayed until an operation is performed. ••Hold: The information is displayed and remains, even an operation is performed. Sets the display background type to A or B. ••A: D isplay background color is black. ••B: D isplay background color is blue. Meter Peak Hold (Default: ON) P25 RX ID Display (Default: Dec) Selects the P25 Talk-group ID display type. ••Dec: In Decimal. ••Hex: In Hexadecimal. Turns the Meter Peak Hold function ON or OFF. ••OFF: Does not hold the peak level. ••ON: Holds the peak level on the signal meter display for 0.5 seconds. Memory Name (Default: ON) Turns the Memory name display in the Memory mode ON or OFF. ••OFF: Memory name is not displayed, even if entered. ••ON: The entered Memory name is displayed above the frequency display. Screen Saver (Default: 60min) Sets the Screen Saver function. This function activates and automatically turns OFF the screen* when no operation is performed for the preset period of time. ••OFF: Turns OFF the function. ••15min: Activates after 15 minutes with no operation. ••30min: Activates after 30 minutes with no operation. ••60min: Activates after 60 minutes with no operation. * indicator blinks. Group Name Popup (Default: ON) Select whether or not to display the group name when you change the memory channel group. ••OFF: The group name is not displayed. ••ON: The group name is displayed. Opening Message (Default: ON) Selects whether or not to display the opening message (including the opening comment) at power ON. • OFF: Opening message is not displayed. • ON: Opening message is displayed. MN-Q Popup (MN OFF→ON) (Default: ON) Selects whether or not to display the Manual Notch filter width when you select the Manual Notch. ••OFF: The Manual Notch filter width is not displayed. ••ON: The Manual Notch filter width is displayed. BW Popup (PBT) (Default: ON) Selects whether or not to display the digital TWIN PBT shift value while rotating TWIN PBT CLR . ••OFF: The the PBT and center shift value are not displayed. ••ON: The the PBT and center shift value are displayed. Opening Comment Enter the opening comment displayed with the opening message at power ON. LPush to change the keyboard type. LRefer to page 1-7 for the character entering. Display Language (Default: English) Sets the display language. • English: Displays in English. • Japanese: Displays in Japanese. LThis item is not displayed when "English" is selected in the "System Language" item. System Language (Default: English) BW Popup (FIL) (Default: ON) Sets the system language. Selects whether or not to display the digital IF filter width and shift value when you change the IF filter. ••OFF: The IF filter width and shift value are not displayed. ••ON: The IF filter width and shift value are displayed. • English: Displays in English. • Japanese: Displays in Japanese. LIf you set the language to English, all Japanese characters (such as memory name) you entered are garbled. But the display returns to normal when you change to Japanese again. 11-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

11
SET MODE
11-9
Displ±y
LCD B±cklight
(Default: 50%)
Sets the LCD backlight brightness.
Range: 0 (dark) ~ 100% (bright)
LED Bright
(Default: 80%)
Sets the LED brightness.
Range: 0 (dark) ~ 100% (bright)
Displ±y Type
(Default: A)
Sets the display background type to A or B.
• A:
Display background color is black.
• B:
Display background color is blue.
Meter Pe±k Hold
(Default: ON)
Turns the Meter Peak Hold function ON or OFF.
OFF:
Does not hold the peak level.
ON:
Holds the peak level on the signal meter
display for 0.5 seconds.
Memory ²±me
(Default: ON)
Turns the Memory name display in the Memory mode
ON or OFF.
OFF:
Memory name is not displayed, even if entered.
• ON:
The entered Memory name is displayed
above the frequency display.
Group ²±me Popup
(Default: ON)
Select whether or not to display the group name when
you change the memory channel group.
OFF:
The group name is not displayed.
• ON:
The group name is displayed.
MN-Q Popup (MN OFF→ON)
(Default: ON)
Selects whether or not to display the Manual Notch
filter width when you select the Manual Notch.
OFF:
The Manual Notch filter width is not displayed.
ON:
The Manual Notch filter width is displayed.
BW Popup (PBT)
(Default: ON)
Selects whether or not to display the digital TWIN PBT
shift value while rotating
TWIN PBT
CLR
.
OFF:
The the PBT and center shift value are not
displayed.
• ON:
The the PBT and center shift value are displayed.
BW Popup (FIL)
(Default: ON)
Selects whether or not to display the digital IF filter
width and shift value when you change the IF filter.
OFF:
The IF filter width and shift value are not displayed.
• ON:
The IF filter width and shift value are displayed.
MENU
»
SET >
Displ±y
RX Popup
(Default: Normal)
Selects whether or not to display the information included
in the received digital signal such as call sign, caller’s ID,
code and so on, when you receive a digital signal.
OFF:
The information is not displayed.
• Normal:
The information is displayed for
approximately 3 seconds.
RX Hold:
The information is displayed until an
operation is performed.
Hold:
The information is displayed and remains,
even an operation is performed.
P25 RX ID Displ±y
(Default: Dec)
Selects the P25 Talk-group ID display type.
• Dec:
In Decimal.
Hex:
In Hexadecimal.
Screen S±ver
(Default: 60min)
Sets the Screen Saver function.
This function activates and automatically turns OFF
the screen* when no operation is performed for the
preset period of time.
OFF:
Turns OFF the function.
15min:
Activates after 15 minutes with no operation.
30min:
Activates after 30 minutes with no operation.
60min:
Activates after 60 minutes with no operation.
*
indicator blinks.
Opening Mess±ge
(Default: ON)
Selects whether or not to display the opening message
(including the opening comment) at power ON.
• OFF: Opening message is not displayed.
• ON:
Opening message is displayed.
Opening Comment
Enter the opening comment displayed with the
opening message at power ON.
L
Push
to change the keyboard type.
L
Refer to page 1-7 for the character entering.
Displ±y L±ngu±ge
(Default: English)
Sets the display language.
• English:
Displays in English.
• Japanese: Displays in Japanese.
L
This item is not displayed when “English” is selected in
the “System Language” item.
System L±ngu±ge
(Default: English)
Sets the system language.
• English:
Displays in English.
• Japanese: Displays in Japanese.
L
If you set the language to English, all Japanese characters
(such as memory name) you entered are garbled. But
the