Icom IC-V8000 Instruction Manual - Page 50

Scan edges programming

Page 50 highlights

7 SCAN OPERATION Scan edges programming Scan edges can be programmed in the same manner as memory channels. Scan edges are programmed into scan edges, 1A/1b to 3A/3b, in memory channels. q Set the edge frequency of the desired frequency range in VFO mode: ➥ Set the frequency using the tuning dial. ➥ Set other data (e.g. repeater settings, etc.) if desired. w Push [MW(S.MW)] momentarily. • "M" indicator and channel number blink. e Rotate the tuning dial to select one of scan edge channel, 1A, 2A or 3A. r Push [MW(S.MW)] for 1 sec. to program. • 3 beeps sound and VFO is automatically selected. • Scan edge 1b, 2b or 3b is automatically selected when continuing to push [MW(S.MW)] after programming. t To program a frequency for the other pair of scan edges, 1b, 2b or 3b, repeat steps q and r. • If the same frequency is programmed into a pair of scan edges, programmed scan will not function. [EXAMPLE]: Programming 145.300 MHz into scan edges 1A. Rotate for setting frequency, etc. Push MW S.MW momentarily. Rotate ➠ Push MW S.MW for 1 sec. and continue to push " " Beep " Beep " Beep " "Beep 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

39
7
SCAN OPERATION
Scan edges programming
Scan edges can be programmed in the same manner as
memory channels. Scan edges are programmed into scan
edges, 1A/1b to 3A/3b, in memory channels.
q
Set the edge frequency of the desired frequency range in
VFO mode:
Set the frequency using the tuning dial.
Set other data (e.g. repeater settings, etc.) if desired.
w
Push [MW(S.MW)] momentarily.
•“
M
indicator and channel number blink.
e
Rotate the tuning dial to select one of scan edge channel,
1A, 2A or 3A.
r
Push [MW(S.MW)] for 1 sec. to program.
3 beeps sound and VFO is automatically selected.
Scan edge 1b, 2b or 3b is automatically selected when continu-
ing to push [MW(S.MW)] after programming.
t
To program a frequency for the other pair of scan edges,
1b, 2b or 3b, repeat steps
q
and
r
.
If the same frequency is programmed into a pair of scan edges,
programmed scan will not function.
[EXAMPLE]:
Programming 145.300 MHz into scan edges 1A.
Push
momentarily.
Rotate
for setting frequency, etc.
Rotate
S.MW
MW
Push
for 1 sec. and continue to push
S.MW
MW
Beep
Beep
Beep
“±
Beep
“±
“±
“±
“±
“±