Icom IC-V8000 Instruction Manual - Page 75

Auto power OFF, Repeater lockout, Squelch delay, DTMF speed

Page 75 highlights

OTHER FUNCTIONS 12 D Auto power OFF The transceiver can be set to automatically turn OFF after a specified period with a beep when no key operations are performed. 30 min., 1 hour, 2 hours and OFF (default) can be specified. The specified period is retained even when the transceiver is turned OFF by the auto power OFF function. To cancel the function, select "OF" in this set mode. D Squelch delay Selects squelch delay from short and long to prevent repeated opening and closing of the squelch during reception of the same signal. • S : Short squelch delay. (default) • L : Long squelch delay D Repeater lockout Selects lockout type from repeater, busy and OFF. • OF : No lockout is activated. (default) • RP : The repeater lockout is turned ON. • BU : The busy lockout is turned ON. Short squelch delay setting Long squelch delay setting D DTMF speed The rate at which DTMF memories send individual DTMF characters can be set to accommodate operating needs. • 1 : 100 msec. interval; 5.0 cps speed (default) 12 • 2 : 200 msec. interval; 2.5 cps speed • 3 : 300 msec. interval; 1.6 cps speed • 5 : 500 msec. interval; 1.0 cps speed Busy lock-out setting Repeater lock-out setting 64

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

64
12
OTHER FUNCTIONS
12
D
Auto power OFF
The transceiver can be set to automatically turn OFF after a
speci
ed period with a beep when no key operations are per-
formed.
30 min., 1 hour, 2 hours and OFF (default) can be speci
ed.
The speci
ed period is retained even when the transceiver is
turned OFF by the auto power OFF function. To cancel the
function, select
OF
in this set mode.
D
Repeater lockout
Selects lockout type from repeater, busy and OFF.
OF
: No lockout is activated. (default)
RP
: The repeater lockout is turned ON.
BU
: The busy lockout is turned ON.
D
Squelch delay
Selects squelch delay from short and long to prevent re-
peated opening and closing of the squelch during reception
of the same signal.
S
: Short squelch delay. (default)
L
: Long squelch delay
D
DTMF speed
The rate at which DTMF memories send individual DTMF
characters can be set to accommodate operating needs.
1
: 100 msec. interval; 5.0 cps speed (default)
2
: 200 msec. interval; 2.5 cps speed
3
: 300 msec. interval; 1.6 cps speed
5
: 500 msec. interval; 1.0 cps speed
Short squelch delay setting
Long squelch delay setting
Busy lock-out setting
Repeater lock-out setting