Icom IC-V8000 Instruction Manual - Page 74

Key-touch beep, Time-out timer, Auto repeater

Page 74 highlights

12 OTHER FUNCTIONS D Key-touch beep The key-touch beep can be turned OFF for silent operation. (default: ON) D Time-out timer To prevent accidental prolonged transmission, etc., the transceiver has a time-out timer. This function cuts a transmission OFF after 1-30 min. of continuous transmission. This timer can be cancelled. • TOT-OF : The time-out timer is turned OFF. (default) • TOT-1-30 : The transmission is cut OFF after the set period elapses. D Auto repeater U.S.A. and C.S.A. versions only The auto repeater function automatically turns ON or OFF the duplex operation with a specified shift direction and tone en- coder, when the operating frequency falls within or outside of 145.200-145.495 MHz, 146.610-146.995 MHz and 147.000-147.395 MHz range. The offset and repeater tone frequencies are not changed by the auto repeater function, reset these frequencies, if necessary. • OF : The auto repeater function is turned OFF. • R1 : Activates for duplex only. (default) • R2 : Activates for duplex and tone. 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

63
12
OTHER FUNCTIONS
D
Key-touch beep
The key-touch beep can be turned OFF for silent operation.
(default: ON)
D
Time-out timer
To prevent accidental prolonged transmission, etc., the trans-
ceiver has a time-out timer. This function cuts a transmission
OFF after 1
30 min. of continuous transmission. This timer
can be cancelled.
TOT-OF
: The time-out timer is turned OFF. (default)
TOT-1
30
: The transmission is cut OFF after the set
period elapses.
D
Auto repeater
The auto repeater function automatically turns ON or OFF the
duplex operation with a speci
ed shift direction and tone en-
coder, when the operating frequency falls within or outside of
145.200
145.495 MHz,
146.610
146.995 MHz
and
147.000
147.395 MHz range. The offset and repeater tone
frequencies are not changed by the auto repeater function,
reset these frequencies, if necessary.
OF
: The auto repeater function is turned OFF.
R1
: Activates for duplex only. (default)
R2
: Activates for duplex and tone.
U.S.A. and C.S.A. versions only