Intel SPSH4 Product Guide - Page 114

Installing a 5.25-inch Peripheral Drive

Page 114 highlights

Installing a 5.25-inch Peripheral Drive CAUTION To avoid damage to a 5.25-inch peripheral drive, ensure that the EMI gasket provided in the front of the lower bay does not bridge or short any open circuits on the peripheral drive. If the drive has open circuits, install it in one of the two upper peripheral drive bays. To install a peripheral drive: 1. Turn off power to the server and unplug the AC power cords from the power source. 2. Remove the front access cover (page 67). 3. Remove the fan modules and the foam fan baffle (page 119). 4. If the drive bay is covered by a metal EMI shield, insert your finger in the large hole in one end of the shield and pull the shield from the chassis. Save the shield. 5. If the drive bay has an existing drive installed, remove the drive (page 113) and remove the slide rails attached to the sides of the drive. Save the rails and screws. 6. Remove the new drive from its protective wrapper and place it on an antistatic surface. 7. Record the new drive model and serial numbers in your equipment log. 8. Set any jumpers or switches on the new drive according to the drive manufacturer instructions. 9. Attach a slide rail to each side of the drive using two mounting screws. C C B A A Data cable B Power cable C Slide rails OM13414 Figure 46. Installing a 5.25-inch Peripheral Drive 10. Position the drive so the plastic slide rails engage the guide rails in the peripheral bay. Push the drive into the bay until the slide rails lock in place. 11. Connect the signal and power cables to the drive. You can insert the keyed connectors only one way. 12. Install the foam fan baffle, fan modules, and the front access cover. 114 Intel SPSH4 Server Platform Product Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170

114
Intel SPSH4 Server Platform Product Guide
Installing a 5.25-inch Peripheral Drive
CAUTION
To avoid damage to a 5.25-inch peripheral drive, ensure that the EMI gasket provided in the
front of the lower bay does not bridge or short any open circuits on the peripheral drive.
If
the drive has open circuits, install it in one of the two upper peripheral drive bays.
To install a peripheral drive:
1.
Turn off power to the server and unplug the AC power cords from the power source.
2.
Remove the front access cover (page 67).
3.
Remove the fan modules and the foam fan baffle (page 119).
4.
If the drive bay is covered by a metal EMI shield, insert your finger in the large hole in one end
of the shield and pull the shield from the chassis.
Save the shield.
5.
If the drive bay has an existing drive installed, remove the drive (page 113) and remove the
slide rails attached to the sides of the drive.
Save the rails and screws.
6.
Remove the new drive from its protective wrapper and place it on an antistatic surface.
7.
Record the new drive model and serial numbers in your equipment log.
8.
Set any jumpers or switches on the new drive according to the drive manufacturer instructions.
9.
Attach a slide rail to each side of the drive using two mounting screws.
OM13414
C
C
B
A
A
Data cable
C
Slide rails
B
Power cable
Figure 46.
Installing a 5.25-inch Peripheral Drive
10. Position the drive so the plastic slide rails engage the guide rails in the peripheral bay.
Push the
drive into the bay until the slide rails lock in place.
11. Connect the signal and power cables to the drive.
You can insert the keyed connectors only
one way.
12. Install the foam fan baffle, fan modules, and the front access cover.