Intel SPSH4 Product Guide - Page 158
Table 21., Error Messages and Codes, Error Message, Failure Description
UPC - 735858156462
View all Intel SPSH4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 158 highlights
Table 21. Error Messages and Codes (Continued) Code 0B1B: 0B1C: 0B50: 0B51: 0B52: Error Message PCI System Error on Bus/Device/Function PCI Parity Error in Bus/Device/Function Processor 1 with error taken offline Processor 2 with error taken offline Processor 3 with error taken offline Failure Description PCI system error in Bus/device/Function PCI system error in Bus/device/Function Failed Processor 1, error detected. Failed Processor 2, error detected. Failed Processor 3, error detected. 0B53: 0B5F: 0B60: 0B61: Processor 4 with error taken offline Forced to use CPU with error DIMM bank 1 has been disabled DIMM bank 2 has been disabled Failed Processor 4,n error detected. An error detected in the entire CPU. Memory error, memory bank 1 failed Memory error, memory bank 2 failed 0B62: 0B6F: 0B70: 0B71: 0B74: 0B75: 0B7C: 0B80: 0B81: 0B82: DIMM bank 3 has been disabled DIMM bank with error is enabled The error occurred during temperature sensor reading System temperature out of the range The error occurred during voltage sensor reading System voltage out of the range The error occurred during redundant power module confirmation BMC Memory Test Failed BMC Firmware Code Area CRC check failed BMC core Hardware failure Memory error, memory bank 3 failed An error detected in all the memory Error while detecting a temperature failure. Temperature error detected. Error while detecting voltage System voltage error The error occurred while retrieving the power information. BMC device (chip) failed BMC device(chip) failed BMC device(chip) failed 0B83: 0B90: 0B91: 0B92: BMC IBF or OBF check failed BMC Platform Information Area corrupted. BMC update firmware corrupted. Internal Use Area of BMC FRU corrupted. 0B93: 0B94: BMC SDR Repository empty. IPMB signal lines do not respond. 0B95 BMC FRU device failure. 0B96 BMC SDR Repository failure. Access to BMC address failed BMC device(chip) failed BMC device(chip) failed SROM storing chassis information failed (Available for use except for FRU command and emergency management port function) BMC device (chip) failed SMC (Satellite Management Controller) failed (Available for use except for the access function to SMC via IPMB) SROM storing chassis information failed (Available for use except for FRU command and emergency management port function.) BMC device (chip) failed 0B97 0BB0: 0BB1: BMC SEL device failure. SMBIOS - SROM data read error SMBIOS - SROM data checksum bad BMC device (chip) failed SROM data read error Bad checksum of SROM data continued 158 Intel SPSH4 Server Platform Product Guide