Removing and Installing Hot-Swap Disk Drives, CAUTION

Page 88 highlights

Removing and Installing Hot-Swap Disk Drives CAUTION Do not leave any drive slots without a drive or air baffle installed in the carrier. An empty carrier installed in a drive slot reduces cooling efficiency and can affect performance or cause damage due to overheating. To replace a hot-swap disk drive: 1. Depress the green clip at the end of the plastic carrier handle. Pull the handle out to disengage the carrier handle latch from the locking slot at the top of the drive bay (Figure 24, B and C). C B A A Handle C Locking slot B Latch Figure 24. Removing a Drive Carrier 2. Carefully pull on the carrier handle and slide the carrier out of the bay. 3. Install a new drive into the carrier (page 86). OM13392 88 Intel SPSH4 Server Platform Product Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170

88
Intel SPSH4 Server Platform Product Guide
Removing and Installing Hot-Swap Disk Drives
CAUTION
Do not leave any drive slots without a drive or air baffle installed in the
carrier.
An empty carrier installed in a drive slot reduces cooling efficiency
and can affect performance or cause damage due to overheating.
To replace a hot-swap disk drive:
1.
Depress the green clip at the end of the plastic carrier handle.
Pull the handle out to disengage
the carrier handle latch from the locking slot at the top of the drive bay (Figure 24, B and C).
OM13392
A
B
C
A
Handle
C
Locking slot
B
Latch
Figure 24.
Removing a Drive Carrier
2.
Carefully pull on the carrier handle and slide the carrier out of the bay.
3.
Install a new drive into the carrier (page 86).