Intel SPSH4 Product Guide - Page 30

General Site Criteria, In the United States and Canada

Page 30 highlights

Table 2. SPSH4 Server Physical Specifications Specification Rack Mount Height 12.25 inches (311 mm) (7U) Width Fits 19-inch rack Depth 25.25 inches (641 mm) Weight Minimum configuration 90 pounds (41 kg) Maximum configuration 119 pounds (57 kg) Required front clearance 3 inches (76 mm), inlet airflow

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170

30
Intel SPSH4 Server Platform Product Guide
Table 2.
SPSH4 Server Physical Specifications
Specification
Rack Mount
Pedestal
Height
12.25 inches (311 mm) (7U)
18.09 inches (459 mm)
Width
Fits 19-inch rack
12.24 inches (311 mm)
Depth
25.25 inches (641 mm)
25.25 inches (641 mm)
Weight
Minimum configuration
Maximum configuration
90 pounds (41 kg)
119 pounds (57 kg)
96 pounds (44 kg)
125 pounds (57 kg)
Required front clearance
3 inches (76 mm), inlet airflow <35 °C
(95 °F)
12 inches (305 mm)
Required rear clearance
4.5 inches (114 mm), no airflow
restriction
9 inches (229 mm)
Required side clearance
0 inch (0 mm)
0 inch (0 mm)
Power requirements
Voltage (110)
Voltage (220)
Frequency
90 V
rms
min, 132 V
rms
max, 9 A
rms
*
180 V
rms
min, 264 V
rms
max, 4.5 A
rms
*
47 Hz min, 63 Hz max
* Amperage is total system power, with
two or three power supply modules
installed.
90 V
rms
min, 132 V
rms
max, 9 A
rms
*
180 V
rms
min, 264 V
rms
max, 4.5
A
rms
*
47 Hz min, 63 Hz max
* Amperage is total system power, with
two or three power supply modules
installed.
For detailed information on calculating power consumption for specific server configurations, see
page 163.
General Site Criteria
The server operates reliably within normal office environmental limits.
Select a site that meets
these criteria:
Near a properly grounded, three-pronged power outlet.
In the United States and Canada:
a NEMA 6-15R outlet for 100-120 V and for 200-240 V.
In other geographic areas:
a properly grounded outlet in accordance with the local
electrical authorities and electrical code of the region.
Clean and relatively free of excess dust.
Well ventilated and away from sources of heat, with the ventilating openings on the server kept
free of obstructions.
Maximum ambient air temperature should not exceed 35 °C (95 °F).
Away from sources of vibration or physical shock.
Isolated from strong electromagnetic fields and noise caused by electrical devices such as
elevators, copy machines, air conditioners, large fans, large electric motors, radio and TV
transmitters, and high-frequency security devices.
Access space provided so the server power cords can be unplugged from the power supply or
the wall outlet; this is the only way to remove AC power from the server.
Clearance provided for cooling and airflow.