Intel SR1600UR Service Guide - Page 123
System Environmental Specifications
UPC - 735858206723
View all Intel SR1600UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
System Environmental Specifications Table 7. System Environmental Specifications Temperature Non-operating Operating Humidity Non-operating Shock Operating Packaged Unpackaged Acoustic noise Electrostatic discharge (ESD) System Cooling Requirement in BTU/Hr -40° to 70°C. 10°C to 35°C with the maximum rate of change not to exceed 10°C per hour 90% relative humidity (non-condensing) at 35°C. 2.0 g, 11 msec, half sine Non-palletized free fall in height 24 inches (> 40 lbs to < 80 lbs) Trapezoidal, 25 g, velocity change 136 inches/sec (> 40 lbs to < 80 lbs) Sound Power: 7.0 BA in an idle state at typical office ambient temperature (23 +/- 2°C). +/-15 KV except I/O port +/- 8 KV per Intel® Environment test specification. 2550 BTU/Hr Intel® Server System SR1600UR Service Guide 105