Cable Routing, Fixed Mount Hard Drive System

Page 48 highlights

Cable Routing When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing. Fixed Mount Hard Drive System Use the following figure to determine the correct cable routing for a fixed mount hard drive system. B A A Intel® Remote Management Module 3 B I/O Module C Power Supply D Fan Board E Power to Server Board (Aux. - P4) F Power to Server Board (Main - P1) G Power to Server Board (CPU - P2) H Power to Fan Board (P3) I Fan Power Cables J Control Panel USB K Control Panel Data L Power to Fixed HDD 0 M SATA Data to Fixed HDD 0 N Power to Fixed HDD 1 O SATA Data to Fixed HDD 1 P Power to Fixed HDD 2 Q SATA Data to Fixed HDD 2 R SATA Data to Optical Drive LS Power to Optical Drive C Power Supply Server Board CPU1 E F G H LM R S HDD0 Optical Drive Module CPU2 Fan Module D I Fan Board NO HDD1 PQ HDD2 J K Drive Bays Control Panel Module Figure 16. Cable Routing (Fixed Mount Hard Drive System) AF002876 30 Intel® Server System SR1600UR Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

30
Intel
®
Server System SR1600UR Service Guide
Cable Routing
When you add or remove components from your server system, make sure your cables are
routed correctly before reinstalling the server system cover. Use caution to make sure no
cables or wires are pinched and that the airflow from the fans is not blocked. Use the
figures below to determine the correct cable routing.
Fixed Mount Hard Drive System
Use the following figure to determine the correct cable routing for a fixed mount hard
drive system.
Figure 16. Cable Routing (Fixed Mount Hard Drive System)
AF002876
A
B
I/O Module
C
Power Supply
D
Fan Board
Power to Server Board (Aux. - P4)
Power to Server Board (Main - P1)
Power to Server Board (CPU - P2)
Power to Fan Board (P3)
Fan Power Cables
Control Panel USB
Control Panel Data
Power to Fixed HDD 0
SATA Data to Fixed HDD 0
Power to Fixed HDD 1
SATA Data to Fixed HDD 1
SATA Data to Optical Drive
Intel® Remote Management Module 3
F
G
H
I
J
K
L
M
N
O
P
Q
R
L
E
Power to Fixed HDD 2
SATA Data to Fixed HDD 2
Drive Bays
Optical
Drive
Module
Control
Panel
Module
CPU2
CPU1
Server
Board
Power
Supply
Fan Module
A
B
F
E
G
H
L
M
N
P
Q
J
K
I
O
Fan Board
HDD0
HDD1
HDD2
R
S
C
D
Power to Optical Drive
S