Intel SR1600UR Service Guide - Page 71
rotations, IMPORTANT - 1u
UPC - 735858206723
View all Intel SR1600UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
To install the heatsink, follow these steps: 1. Remove the protective film on the TIM, if present. 2. Orient the heatsink over the processor as shown in Figure 41. The heatsink fins must be positioned as shown to provide correct airflow through the system. 3. Set the heatsink over the processor, lining up the four captive screws with the four posts surrounding the processor. 4. Loosely screw in the captive screws on the heatsink corners in a diagonal manner according to the numbers shown in Figure 41 as follows: a. Starting with the screw at location 1, engage the screw threads by giving it two rotations in the clockwise direction and stop. (IMPORTANT: Do not fully tighten.) b. Proceed to the screw at location 2 and engage the screw threads by giving it two rotations and stop. c. Engage screws at locations 3 and 4 by giving each screw two rotations and then stop. d. Repeat steps 4a through 4c by giving each screw two rotations each time until all screws are lightly tightened upto a maximum of 8 inch-lbs torque. 3 2 Air Flow 1 4 TIM Chassis Front AF002841 Figure 41. Installing the Heatsink (1U Passive Heatsink Shown) Intel® Server System SR1600UR Service Guide 53