Intel SR1600UR Service Guide - Page 67

Removing DIMMs, Installing and Removing the Processor, Installing the Processor

Page 67 highlights

6. Position the DIMM above the socket. Align the notch on the bottom edge of the DIMM with the key in the DIMM socket (see letter "B" in Figure 34 - the arrow is pointing to the key in the socket). 7. Insert the bottom edge of the DIMM into the socket. 8. When the DIMM is correctly positioned, push down on the top edge of the DIMM until the retaining clips snap into place (see letter "C" in Figure 34). 9. Make sure the clips are firmly in place (see letter "D" in Figure 34). Removing DIMMs To remove a DIMM, follow these steps: 1. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly" on page 41. 2. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct" on page 46. 3. Locate the DIMM sockets (see Figure 34). 4. Gently spread the retaining clips at each end of the socket. The DIMM lifts from the socket. 5. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. Installing and Removing the Processor Caution: Processor must be appropriate: You may damage the server board if you install a processor that is inappropriate for your server. See "Additional Information and Software" on page 3 for a web link to the list of compatible processor(s). Caution: ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to the processor by doing the following: (1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor. (2) Avoid moving around unnecessarily. Caution: Protective socket cover needs to be removed for proper cooling of the processor; failure to remove the cover could result in damage to the system. Installing the Processor To install a processor, follow these instructions: 1. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly" on page 41. Intel® Server System SR1600UR Service Guide 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

Intel
®
Server System SR1600UR Service Guide
49
6.
Position the DIMM above the socket. Align the notch on the bottom edge of the
DIMM with the key in the DIMM socket (see letter “B” in
Figure 34
- the arrow is
pointing to the key in the socket).
7.
Insert the bottom edge of the DIMM into the socket.
8.
When the DIMM is correctly positioned, push down on the top edge of the DIMM
until the retaining clips snap into place (see letter “C” in
Figure 34
).
9.
Make sure the clips are firmly in place (see letter “D” in
Figure 34
).
Removing DIMMs
To remove a DIMM, follow these steps:
1.
Remove the PCI riser assembly. For instructions, see
“Removing the PCI Riser
Assembly” on page 41
.
2.
Remove the processor air duct. For instructions, see
“Removing the Processor Air
Duct” on page 46
.
3.
Locate the DIMM sockets (see
Figure 34
).
4.
Gently spread the retaining clips at each end of the socket. The DIMM lifts from
the socket.
5.
Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static
package.
Installing and Removing the Processor
Caution:
Processor must be appropriate: You may damage the server board if you install a
processor that is inappropriate for your server. See
“Additional Information and
Software” on page 3
for a web link to the list of compatible processor(s).
Caution:
ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to
the processor by doing the following: (1) Touch the metal chassis before touching the
processor or server board. Keep part of your body in contact with the metal chassis to
dissipate the static charge while handling the processor. (2) Avoid moving around
unnecessarily.
Caution:
Protective socket cover needs to be removed for proper cooling of the processor; failure to
remove the cover could result in damage to the system.
Installing the Processor
To install a processor, follow these instructions:
1.
Remove the PCI riser assembly. For instructions, see
“Removing the PCI Riser
Assembly” on page 41
.