Intel SR1600UR Service Guide - Page 132
Diagnostic LED Placement Diagram, Table 9. Diagnostic LED POST Code Decoder
![]() |
UPC - 735858206723
View all Intel SR1600UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 132 highlights
AB C A. System Status LED C. POST Code Diagnostic LEDs B. System Identification LED Figure 89. Diagnostic LED Placement Diagram AF003045 Table 9. Diagnostic LED POST Code Decoder Diagnostic LED Decoder O=On; X=Off Checkpoint Upper Nibble MSB Lower Nibble LSB Description 8h 4h 2h 1h 8h 4h 2h 1h LED #7 #6 #5 #4 #3 #2 #1 #0 Multi-Use Code (This beep code is used in different contexts) 0xF2h O O O O X X OX Memory Error Codes (Accompanied by a beep code) 0xE8h O O O X O XXX OxEAh O O O X O X OX 0xEBh O O O X O X OO Seen at the start of Memory Reference Code (MRC) Start of the very early platform initialization code Very late in POST, it is the signal that the OS has switched to virtual memory mode No Usable Memory Error: No memory in the system, or SPD bad so no memory could be detected Channel Training Error: DQ/DQS training failed on a channel during memory channel initialization. Memory Test Error: memory failed Hardware BIST. 114 Intel® Server System SR1600UR Service Guide
![](/manual_guide/products/intel-sr1600ur-service-guide-487b644/132.png)