Sharp AR-M280 AR-M280 AR-M350 AR-M450 Operation Manual (for multifunction - Page 63
Misfeed in the duplex module
View all Sharp AR-M280 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
MISFEED REMOVAL Misfeed in the duplex module 1 Pull out the duplex module. Hold the knob and gently open the module. 5 Gently close the duplex module. After closing the duplex module, confirm that the misfeed message is cleared and that the normal display appears. 2 Raise the exit tray and open the cover of the duplex module. If the duplex module is not equipped with an exit tray, the operation concerning the exit tray is not needed (steps 2 to 4). 3 While holding the exit tray up, remove the misfed paper. q If paper is misfed at the upper part of the duplex module: Gently remove the misfed paper taking care not to tear the paper. s Misfeed in the bypass tray 1 Remove the misfed from the bypass tray. Be careful not to tear the misfed paper during removal. 4 2 Open and close the duplex module to clear the misfeed message. q If paper is misfed at the lower part of the duplex module: Gently remove the misfed paper taking care not to tear the paper. 4 Close the cover of the duplex module and return the exit tray. 4-7