2. Communication section Note: These items are factory adjusted when shipping according to FCC standards. Therefore, do not change the setting in the market. A. Dial test ( SIM 66-14, 16) (1) Dial pulse transmission test 1) Execute SIM 66-14 in FAX mode. 2) Select the item with the 10-key, and press the [START] key. 3) Set the make time with the 10-key. The dial is sent with the set value + 26ms. The sending dial cannot be interrupted. SIM Soft Initial SW value Set value Dial 10 FAX SW 25- 40ms SW set value: 0 to 15 1ms step pulse PPS mode 1 to 4 (14) Make time: 26 to (Binary make 66-14 41ms input) time (2) DTMF signal transmission level adjustment 1) Execute SIM 66-16 in the FAX mode. 2) Select the item with the 10-key, and press the [START] key. 1 3) Enter the set value with the 10-key, and press the [START] key. The sending dial cannot be interrupted. 4) Select the soft SW reflection. DTMF transmission level SIM Soft SW High (FAX SW 64- group mode) 66- 4 to 8 16 (Test only) High SW 65- group 5 to 8 - Low group Initial value Set value -6dBm SW set value: 0 to 21 Transmission level: 0.0 to -21dB +2.0 SW set value: dBm 0 to 15 Transmission level: 2.0 to 5.5dB 1dBm step (Binary input) 0.5dBm step (Binary input) AR-FX7 ADJUSTMENTS 5 - 2