Sharp AR-MM9 Service Manual - Page 22

New Zealand : 010

Page 22 highlights

1 66-2 Purpose Adjustment Function Used to clear the FAX-related soft SW. (Except for the (Purpose) FAX adjustment values) Section FAX Operation/procedure 1. Enter the country code with the 10-key, and press the [START] key. 2. When "1: (YES)" is selected, the soft SW corresponding to the country code is cleared. When "2: (NO)" is selected, the simulation is canceled. Country code Japan : 00000000 U.S.A. : 10110101 Australia : 00001001 U.K : 10110100 France : 00111101 Germany : 00000100 Sweden : 10100101 New Zealand : 01111110 China : 00100110 Singapore : 10011100 TW : 11111110 Other 1 : 11111101 Other 2 : 11111100 Other 3 : 11111011 The codes other than the above are accepted as Japan. Note: Executable only when the FAX is installed. 12345678 00001001 66-3 Purpose Function (Purpose) Section Item Operation/procedure Operation test/check FAX PWB memory check FAX Operation Press the [START] key. Read/write can be checked for FAX PWB memory. The check result is displayed separately for each memory. 1. Memory to be checked DRAM SRAM Flash ROM Option memory Program area Memory area PAGE SUM check only The memory size follows the automatically detected value. 2. Detailed procedure 1 "55H" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written. 2 "AAH" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written. 3 "00H" is written to all the addresses of each memory, and the address data are read in sequence to check that they were properly written. 4 Perform checks 1 - 3 sequentially. If there is no abnormality, it is "OK." If there is any abnormality, "NG" is notified to the error address. 5 After completion of check, the memory is returned to the initial state. (CPU is not reset) Interruption cannot be made during operation. Note: Executable only when the FAX is installed. 1 66-4 Purpose Function (Purpose) Section Item Operation test/check Signal send mode (Signal send level: Max.) FAX Operation Operation/procedure Select the signal number with the 10-key, and press the [START] key. The signal is sent to the line and the machine speaker. (Sending the signal is continued until the [CUSTOM SETTINGS] key is pressed.) By entering the signal number and pressing the [START] key during execution, the signal kind can be changed. Item Send signal 1 NO SIGNAL Signal not sent 2 33.6 V34 - 3 31.2 V34 - 4 28.8 V34 - 5 26.4 V34 - 6 24.0 V34 - 7 16.0 V34 - 8 19.2 V34 - 9 16.8 V34 - 10 14.4 V34 - 11 12.0 V34 - 12 9.6 V34 - 13 7.2 V34 - 14 4.8 V34 - 15 2.4 V34 - 16 14.4 V33 - 17 12.0 V33 - 18 14.4 V17 - 19 12.0 V17 - 20 9.6 V17 - 21 7.2 V17 - 22 9.6 V29 - 23 7.2 V29 - 24 4.8 V27t - Send level Selection menu None AR-FX7 SIMULATION 6 - 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

AR-FX7
SIMULATION
6 - 6
Operation/procedure
1.
Enter the country code with the 10-key, and press the [START]
key.
2.
When "1: (YES)" is selected, the soft SW corresponding to the
country code is cleared. When "2: (NO)" is selected, the simulation
is canceled.
Country code
The codes other than the above are accepted as Japan.
Note: Executable only when the FAX is installed.
Operation/procedure
Press the [START] key.
Read/write can be checked for FAX PWB memory.
The check result is displayed separately for each memory.
1.
Memory to be checked
2.
Detailed procedure
Interruption cannot be made during operation.
Note: Executable only when the FAX is installed.
Operation/procedure
Select the signal number with the 10-key, and press the [START] key.
The signal is sent to the line and the machine speaker. (Sending the
signal is continued until the [CUSTOM SETTINGS] key is pressed.)
By entering the signal number and pressing the [START] key during
execution, the signal kind can be changed.
66-2
Purpose
Adjustment
Function
(Purpose)
Used to clear the FAX-related soft SW. (Except for the
FAX adjustment values)
Section
FAX
Japan
: 00000000
U.S.A.
: 10110101
Australia
: 00001001
U.K
: 10110100
France
: 00111101
Germany
: 00000100
Sweden
: 10100101
New Zealand : 01111110
China
: 00100110
Singapore
: 10011100
TW
: 11111110
Other 1
: 11111101
Other 2
: 11111100
Other 3
: 11111011
66-3
Purpose
Operation test/check
Function (Purpose)
FAX PWB memory check
Section
FAX
Item
Operation
DRAM
SRAM
Flash ROM
Program area
SUM check only
Memory area
Option memory
The memory size follows the
automatically detected value.
PAGE
1
00001001
1
23
4
5
67
8
1
"55H" is written to all the addresses of each memory, and the
address data are read in sequence to check that they were
properly written.
2
"AAH" is written to all the addresses of each memory, and the
address data are read in sequence to check that they were
properly written.
3
"00H" is written to all the addresses of each memory, and the
address data are read in sequence to check that they were
properly written.
4
Perform checks 1 - 3 sequentially. If there is no abnormality, it is
"OK." If there is any abnormality, "NG" is notified to the error
address.
5
After completion of check, the memory is returned to the initial
state.
(CPU is not reset)
66-4
Purpose
Operation test/check
Function
(Purpose)
Signal send mode (Signal send level: Max.)
Section
FAX
Item
Operation
Item
Send signal
Send level
Selection
menu
1
NO SIGNAL
Signal not sent
None
2
33.6 V34
3
31.2 V34
4
28.8 V34
5
26.4 V34
6
24.0 V34
7
16.0 V34
8
19.2 V34
9
16.8 V34
10
14.4 V34
11
12.0 V34
12
9.6 V34
13
7.2 V34
14
4.8 V34
15
2.4 V34
16
14.4 V33
17
12.0 V33
18
14.4 V17
19
12.0 V17
20
9.6 V17
21
7.2 V17
22
9.6 V29
23
7.2 V29
24
4.8 V27t
1