Sharp AR-MM9 Service Manual - Page 27
Select the set volume. Max., Middle, Min.
UPC - 074000074828
View all Sharp AR-MM9 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Item Content 4 PROTOCOL Protocol error list Regardless of soft SW38-1 status, the protocol monitor of the preceding communication is printed. (Printing is allowed at any time before starting the next communication.) For this operation, the protocol monitor of one communication is always buffered. Note: Executable only when the FAX is installed. 66-22 Purpose Setting Function Handset sound volume adjustment (Japan only) (Purpose) Section FAX Item Operation Operation/procedure 1. Select the set volume. (Max., Middle, Min.) 2. Press the [START] key. Switch of 1, 2, and 3 can be made during execution of the simulation. During execution of the simulation, sounds are generated. Note: Executable only when the FAX is installed. 66-24 Purpose Data clear Function Used to clear the FAST storage data. (SEC only) (Purpose) Section FAX Item Data Initializing Operation/procedure Select "1: YES" with the 10-key and press the [START] key. The FAST storage data are cleared. (When "2: NO" is selected, the simulation is canceled.) Note: Executable only when the FAX is installed. 66-30 Purpose Function (Purpose) Section Item Operation/procedure Operation test/check Used to set the TEL/LIU. FAX Operation When the relay state of the polarity reverse relay, the handset hook switch, or the external telephone hook switch is changed, the content of change is displayed regardless of the soft SW setup (real time). The display of change is kept until an interruption command is supplied by pressing the [CUSTOM SETTINGS] key. Item HS2 HS1 RHS EXHS Notification contents Signal low Signal high ON OFF ON OFF ON OFF ON OFF Note: Executable only when the FAX is installed. 66-31 Purpose Setting Function (Purpose) Used to set the TEL/LIU. Section FAX Item Operation Operation/Procedure 1. Enter the set value. (Valid only 0 to 8) 2. The entered bit is alternatively switched between "0" and 1" and the target signal name is highlighted. 3. Press the [START] key to send the signal. When the [CUSTUM SETTINGS] key is pressed, the output is terminated. Note: Executable only when the FAX is installed. 1 2 3 4 5 00001 66-32 Purpose Operation test/check Function (Purpose) Receive data check Section FAX Item Operation Operation/procedure The fixed data received from the line are checked and the result is displayed. When data are coincident, "OK" is displayed. When not, "NG" is displayed. Note: Executable only when the FAX is installed. AR-FX7 SIMULATION 6 - 11