Sharp AR-MM9 Service Manual - Page 7

Registration system, Telephone function system - international

Page 7 highlights

(11) 2 in 1 reception NO (12) Polling Send request Resolution YES Ultra Fine (Change by the soft SW) (13) Turn around transmission NO 7. Registration system (1) Number registration Rapid dialing Group dialing Program Relay group Number of items (Include group) Number of digits of other party's number User tag classification International communication mode setup Transmission method Registered key Max. number of registration per group dialing Registerable number Registered name User tag classification Transmission method Number of items Registerable items Registered name Call method Change in setup after calling Number of items Registered name Relay station number registration Reception station number registration 500 items 50 digits (+ Sub address 20 digits, pass code 20 digits) YES YES Rapid dialing key + Start key Rapid dialing key 10-key (Not available for sub address) 200 items (The total number of registration is 200 items.) Numbers registered to rapid dialing, and numbers entered with 10-key 36 letters YES Rapid dialing key + Start key 8 items An setup items in transmission excluding time specification/ document size/duplex/job build. 36 letters By pressing program key NO (Change in setup is available for time specification/document size/ duplex/job build. (Specifying page division in registration makes it impossible for duplex/job build.)) 10 groups 36 letters 10-key only 10-key dialing For rapid key dialing/group dialing speed dialing/the numbers registered in relay station must be input. (2) Sender registration Sender's name 20 items (registration/display: 22 letters) Registered by key operator program. Sender's number 20 digits, registered with key operator program (3) Polling (Registration of allow number) Registration of polling allow number System number registration 10 items, 20 digits, registered by key operator program 1 items, 4 digits, registered by key operator program Registration of polling allow ID number Up to 10 items in 4 digits. Registered by key operator program. Relay ID code registration 10 items, 20 digits, registered by key operator program (4) Letter input Key entry Letters allowed for input YES 3 types of keyboard available (5) Registered data read/write YES (Service tool. Dial registration can be made with PC.) (6) Date/time adjustment Registered by key operator program. (7) Backup Backup of registration in power SRAM used, by built-in battery failure 8. Telephone function system Handset On-hook function Reserve Pause Telephone transmission in power failure Sound Ringer volume volume adjustment Line monitor sound Speaker sound Transmission complete sound Transmission complete sound tone setup (transmission end) Transmission complete sound tone setup (reception end) Transmission complete sound time setup Scan end sound Tone pulse switch External telephone connection Remote reception switch Telephone/ Sound Fax response Answering voice recording NO YES NO YES (1 to 15sec: Default 2sec, set by key operator program) NO (However, external telephone transmission is allowed.) YES (Set by key operator program to Large/Medium/Small/No sound.) YES (Set by key operator program to Large/Medium/Small/No sound.) YES (Set by key operator program to Large/Medium/Small.) YES (Set by key operator program to Large/Medium/Small/No sound.) YES (Set by key operator program to PATTERN 1/2/3.) YES (Set by key operator program to PATTERN 1/2/3.) YES (Set by key operator program. 5 step by 2.0 to 4.0 sec.) YES (Set by soft switch to Large/ Medium/Small/No sound.) 10/TONE selection with key operator program. YES YES (Switch number is in 1 digit + ∗∗) 5∗∗ NO NO AR-FX7 SPECIFICATIONS 2 - 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

AR-FX7
SPECIFICATIONS
2 - 3
(11)
2 in 1 reception
(12) Polling
(13)
Turn around transmission
7.
Registration system
(1)
Number registration
(2)
Sender registration
(3)
Polling (Registration of allow number)
(4)
Letter input
(5)
Registered data read/write
(6)
Date/time adjustment
(7) Backup
8.
Telephone function system
NO
Send request
YES
Resolution
Ultra Fine (Change by the soft SW)
NO
Rapid
dialing
Number of items
(Include group)
500 items
Number of digits
of other party
s
number
50 digits (+ Sub address 20 digits,
pass code 20 digits)
User tag
classification
YES
International
communication
mode setup
YES
Transmission
method
Rapid dialing key + Start key
Group
dialing
Registered key
Rapid dialing key
10-key (Not available for sub
address)
Max. number of
registration per
group dialing
200 items (The total number of
registration is 200 items.)
Registerable
number
Numbers registered to rapid dialing,
and numbers entered with 10-key
Registered name
36 letters
User tag
classification
YES
Transmission
method
Rapid dialing key + Start key
Program
Number of items
8 items
Registerable
items
An setup items in transmission
excluding time specification/
document size/duplex/job build.
Registered name
36 letters
Call method
By pressing program key
Change in setup
after calling
NO (Change in setup is available for
time specification/document size/
duplex/job build. (Specifying page
division in registration makes it
impossible for duplex/job build.))
Relay
group
Number of items
10 groups
Registered name
36 letters
Relay station
number
registration
10-key only
Reception
station number
registration
10-key dialing
For rapid key dialing/group dialing
speed dialing/the numbers registered
in relay station must be input.
Sender
s name
20 items (registration/display: 22 letters)
Registered by key operator program.
Sender
s number
20 digits, registered with key operator program
Registration of
polling allow
number
10 items, 20 digits, registered by key operator
program
System number
registration
1 items, 4 digits, registered by key operator
program
Registration of
polling allow ID
number
Up to 10 items in 4 digits. Registered by key
operator program.
Relay ID code
registration
10 items, 20 digits, registered by key operator
program
Key entry
YES
Letters allowed
for input
3 types of keyboard available
YES (Service tool. Dial registration can be made with PC.)
Registered by key operator program.
Backup of registration in power
failure
SRAM used, by built-in battery
Handset
NO
On-hook function
YES
Reserve
NO
Pause
YES (1 to 15sec: Default 2sec, set
by key operator program)
Telephone transmission in
power failure
NO (However, external telephone
transmission is allowed.)
Sound
volume
adjustment
Ringer volume
YES (Set by key operator program
to Large/Medium/Small/No sound.)
Line monitor
sound
YES (Set by key operator program
to Large/Medium/Small/No sound.)
Speaker sound
YES (Set by key operator program
to Large/Medium/Small.)
Transmission
complete sound
YES (Set by key operator program
to Large/Medium/Small/No sound.)
Transmission complete sound
tone setup (transmission end)
YES (Set by key operator program
to PATTERN 1/2/3.)
Transmission complete sound
tone setup (reception end)
YES (Set by key operator program
to PATTERN 1/2/3.)
Transmission complete sound
time setup
YES (Set by key operator program.
5 step by 2.0 to 4.0 sec.)
Scan end sound
YES (Set by soft switch to Large/
Medium/Small/No sound.)
Tone pulse switch
10/TONE selection with key
operator program.
External telephone
connection
YES
Remote
reception switch
YES (Switch number is in 1 digit +
∗∗
) 5
∗∗
Telephone/
Fax
Sound
response
NO
Answering
voice recording
NO