Sharp AR-MM9 Service Manual - Page 35

Sharp AR-MM9 - Memory Board - DRAM Manual

Page 35 highlights

SW Data No. No. Items SW selection and functions 1 Make time (10PPS) setup Binary 2 3 S4 W 25 5 Inhibited to use 6 input Bit No. Setting range 1234 26 to 41ms by increment of 1ms 7 8 1 DTMF signal send time Binary 2 3 S4 input Bit No. Setting range 12345 6 (60ms) to 31 (310ms) X (ms) = (N × 10) W5 26 6 Minimum pause time Binary 7 (DTMF) setup 8 input Bit No. Setting range 678 0 (90ms) to 7 (160ms) X (ms) = (N × 10) + 90 1 Inhibited to use 2 Setting of time before dial Binary 3 (DTMF) S4 W input Bit No. Setting range 234 0 (30ms) to 7 (100ms) X (ms) = (N × 10) + 30 27 5 Setting of DPMUTE OFF Binary 6 time after dial 7 8 input Bit No. Setting range 5678 0 (5ms) to 15 (80ms) X (ms) = (N × 5) + 5 1 Pause time setup Binary 2 input Bit No. 1234 3 Setting range 1 to 15sec 4 5 Flash send time Bit No. 56 S W 28 6 90ms 180ms 270ms 360ms 00 01 10 11 7 Line open delay time in dial Bit No. 78 test 2sec 00 3sec 01 8 4sec 10 5sec 11 1 Communication record 1: Yes 0: No table automatic print 2 Time specification of 1: Allowed 0: Inhibited communication record table 3 Sequence of year, month, Bit No. 34 and day on the LCD, the S report, and the sender's W 4 record 29 Year, month, day Month, day, year Day, month, year 00 01 10 11 5 Call time setup in automatic Binary 6 transmission (T0 timer 7 setup) 8 input Bit No. Setting range 5678 30 to 75sec by increment of 5sec 1 Inhibited to use 2 3 S 4 Time specification print Binary W 30 5 (o'clock) on the input Bit No. 6 communication record table Setting range 7 8 45678 00 to 23 o'clock Default value Remarks 40ms 110ms 120ms 50ms 5ms 2sec 90ms 1 1 1 0 0 0 0 0 0 1 0 1 1 0 1 1 0 0 1 0 0 0 0 0 0 When the value is 0 outside the setting 1 range, the initial 0 value is set. 0 fixed 0 0 0 2sec 0 No 0 Inhibited 0 Month, day, year When the value is 0 outside the setting range, the initial value is set. 1 45sec 0 o'clock 0 When the value is 0 outside the setting 1 range, the initial value is set. 1 (Menu setting in the unit of 15sec) 0 0 0 0 When the value is 0 outside the setting 0 range, the initial 0 value is set. 0 AR-FX7 SOFT SWITCH 7 - 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

AR-FX7
SOFT SWITCH
7 - 7
S
W
25
1
Make time (10PPS) setup
Binary
input
Bit No.
Setting range
1
2
3
4
26 to 41ms
by increment of 1ms
40ms
1
2
1
3
1
4
0
5
Inhibited to use
0
6
0
7
0
8
0
S
W
26
1
DTMF signal send time
Binary
input
Bit No.
Setting range
1
2
3
4
5
6 (60ms) to 31 (310ms)
X (ms) = (N
×
10)
110ms
0
2
1
3
0
4
1
5
1
6
Minimum pause time
(DTMF) setup
Binary
input
Bit No.
Setting range
6
7
8
0 (90ms) to 7 (160ms)
X (ms) = (N
×
10) + 90
120ms
0
7
1
8
1
S
W
27
1
Inhibited to use
0
2
Setting of time before dial
(DTMF)
Binary
input
Bit No.
Setting range
2
3
4
0 (30ms) to 7 (100ms)
X (ms) = (N
×
10) + 30
50ms
0
3
1
4
0
5
Setting of DPMUTE OFF
time after dial
Binary
input
Bit No.
Setting range
5
6
7
8
0 (5ms) to 15 (80ms)
X (ms) = (N
×
5) + 5
5ms
0
6
0
7
0
8
0
S
W
28
1
Pause time setup
Binary
input
Bit No.
Setting range
1
2
3
4
1 to 15sec
2sec
0
When the value is
outside the setting
range, the initial
value is set.
2
0
3
1
4
0
5
Flash send time
Bit No.
5
6
90ms
0
0 fixed
90ms
0
0
180ms
0
1
6
270ms
1
0
0
360ms
1
1
7
Line open delay time in dial
test
Bit No.
7
8
2sec
0
2sec
0
0
3sec
0
1
8
4sec
1
0
0
5sec
1
1
S
W
29
1
Communication record
table automatic print
1: Yes
0: No
No
0
2
Time specification of
communication record table
1: Allowed
0: Inhibited
Inhibited
0
3
Sequence of year, month,
and day on the LCD, the
report, and the sender
s
record
Bit No.
3
4
Month, day, year
0
When the value is
outside the setting
range, the initial
value is set.
Year, month, day
0
0
Month, day, year
0
1
4
Day, month, year
1
0
1
1
1
5
Call time setup in automatic
transmission (T0 timer
setup)
Binary
input
Bit No.
Setting range
5
6
7
8
30 to 75sec
by increment of 5sec
45sec
0
When the value is
outside the setting
range, the initial
value is set.
(Menu setting in the
unit of 15sec)
6
0
7
1
8
1
S
W
30
1
Inhibited to use
0
2
0
3
0
4
Time specification print
(o
clock) on the
communication record table
Binary
input
Bit No.
Setting range
4
5
6
7
8
00 to 23 o
clock
0 o
clock
0
When the value is
outside the setting
range, the initial
value is set.
5
0
6
0
7
0
8
0
SW
No.
Data
No.
Items
SW selection and functions
Default value
Remarks