Brother International HE-800A Instruction Manual - English - Page 60
Production counter
View all Brother International HE-800A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
5. OPERATION 5-10. Production counter Check that panel DIP switch A - No.4 is at the OFF setting. (Refer to "13. CHANGING FUNCTIONS USING THE DIP SWITCHES".) 3941Q 1. Press the SELECT key (1) to change the mode to automatic mode. 2. Press the parameter keys (2) and (3) simultaneously. * "PC" will flash in the program number LED (4), and the production counter value will appear in the parameter display LED (5). 3. Press the parameter keys (2) and (3) to change the production counter setting. * The production counter setting will flash while the setting is being changed. If you would like to set the production counter to "0", press the RESET key (6). 4. Press the ENTER key (7). The production counter value will be accepted and the mode will return to automatic mode. * If you press the SELECT key (1) while the production counter value is still flashing, the mode will return to automatic mode without the production counter value being changed. HE-800A 52