Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 101

Message, Description, Recommended Action

Page 101 highlights

3-34 Compaq ProLiant 6400R Maintenance and Service Guide Table 3-18 ADU Diagnostic Messages continued Message Description Accelerator status: Obsolete data was flushed (written) to drives During reset initialization, obsolete data were found in cache. Obsolete data were written to the drives, but newer data may have been overwritten. Accelerator status: Permanently disabled Array accelerator board has been permanently disabled. It remains disabled until it is reinitialized using the Array Configuration Utility (ACU). Accelerator status: Possible data loss in cache Possible data loss detected during power-up because all batteries are below sufficient voltage level and no presence of identification signatures on the array accelerator board. Accelerator status: Temporarily disabled Array accelerator board has been temporarily disabled. Accelerator status: Unrecognized status A status returned from the array accelerator board that ADU does not recognize. Accelerator status: Valid data found at reset Valid data were found in posted write memory at reinitialization. Data will be flushed to disk. Not an error or data loss condition. Accelerator status: Warranty alert Catastrophic problem with array accelerator board. Refer to other messages on Diagnostics screen for exact meaning of this message. Adapter/NVRAM ID mismatch EISA nonvolatile RAM has an ID for a different controller from the one physically present in the slot. Array accelerator battery pack X not fully charged Battery is not fully charged. Array accelerator battery pack X below reference voltage (recharging) Board in use by expand operation Battery pack on array accelerator is below required voltage levels. Array accelerator memory is in use by Expand operation. Recommended Action If newer data were overwritten, you may need to restore newer data. Otherwise, normal operations should continue. Check the Disable Code field. Run ACU to reinitialize the array accelerator board. There is no way to determine if dirty or bad data were in the cache and are now lost. Check the Disable Code field. Obtain the latest version of ADU. No action required. Replace the array accelerator board. Run the System Configuration Utility. If 75 percent of batteries present are fully charged, array accelerator is fully operational. If less than 75 percent of batteries are fully charged, allow 36 hours to recharge them. Allow enough time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the array accelerator board. Operate system without array accelerator board until Expand operation completes. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173

3-34
Compaq ProLiant 6400R Maintenance and Service Guide
Table 3-18
ADU Diagnostic Messages
continued
Message
Description
Recommended Action
Accelerator
status: Obsolete
data was flushed
(written) to
drives
During reset initialization, obsolete
data were found in cache. Obsolete
data were written to the drives, but
newer data may have been
overwritten.
If newer data were overwritten, you may need
to restore newer data. Otherwise, normal
operations should continue.
Accelerator
status:
Permanently
disabled
Array accelerator board has been
permanently disabled. It remains
disabled until it is reinitialized using
the Array Configuration Utility (ACU).
Check the Disable Code field. Run ACU to
reinitialize the array accelerator board.
Accelerator
status: Possible
data loss in
cache
Possible data loss detected during
power-up because all batteries are
below sufficient voltage level and no
presence of identification signatures
on the array accelerator board.
There is no way to determine if dirty or bad data
were in the cache and are now lost.
Accelerator
status:
Temporarily
disabled
Array accelerator board has been
temporarily disabled.
Check the Disable Code field.
Accelerator
status:
Unrecognized
status
A status returned from the array
accelerator board that ADU does not
recognize.
Obtain the latest version of ADU.
Accelerator
status: Valid data
found at reset
Valid data were found in posted write
memory at reinitialization. Data will
be flushed to disk. Not an error or
data loss condition.
No action required.
Accelerator
status: Warranty
alert
Catastrophic problem with array
accelerator board. Refer to other
messages on Diagnostics screen for
exact meaning of this message.
Replace the array accelerator board.
Adapter/NVRAM
ID mismatch
EISA nonvolatile RAM has an ID for a
different controller from the one
physically present in the slot.
Run the System Configuration Utility.
Array accelerator
battery pack X
not fully charged
Battery is not fully charged.
If 75 percent of batteries present are fully
charged, array accelerator is fully operational. If
less than 75 percent of batteries are fully
charged, allow 36 hours to recharge them.
Array accelerator
battery pack X
below reference
voltage
(recharging)
Battery pack on array accelerator is
below required voltage levels.
Allow enough time for batteries to recharge
(36 hours). If batteries have not recharged after
36 hours, replace the array accelerator board.
Board in use by
expand operation
Array accelerator memory is in use
by Expand operation.
Operate system without array accelerator board
until Expand operation completes.
continued