Diagnostics and Troubleshooting 3-45 Event List The Event List displays the affected components and the associated error messages. Though the same basic information displays, the format of the list may differ, depending on whether you view it on the Integrated Management Display, from within Compaq Insight Manager, or from the Compaq Survey Utility. An example of the format of an event displayed on the Integrated Management Display is as follows: **001 of 010** ---caution--03/19/1997 12:54 PM FAN INSERTED Main System Location: System Board Fan ID: 03 **END OF EVENT** Event Messages Event Type Machine Environment Fan failure Fan inserted Fan removed Fans not redundant Overheat condition Main Memory Correctable error threshold exceeded Table 3-19 Event Messages Event Message System Fan Failure (Fan X, Location). System Fan Inserted (Fan X, Location). System Fan Removed (Fan X, Location). System Fans Not Redundant. System Overheating (Zone X, Location). Corrected Memory Error threshold passed (Slot X, Memory Module X). Corrected Memory Error threshold passed (System Memory). Corrected Memory Error threshold passed (Memory Module unknown). Action Replace fan. None None Add fan. Check fans. Replace the defective memory module. Replace the memory modules one at a time (if more than one), and retest the system after each replacement. Replace the memory modules one at a time (if more than one). continued