Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 79

Error Code, Audible Beeps, Probable Source of Problem, Recommended Action, do

Page 79 highlights

3-12 Compaq ProLiant 6400R Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps 1622-Internal SCSI None Jumper Board Not Installed 1703-SCSI cable None error detected. Internal SCSI cable not attached to system board connector. System halted. 1720-Slot x Drive None Array - SMART Drive Detects Imminent Failure SCSI: Port y: SCSI ID x 1724-Slot x Drive None Array - Physical Drive Position Change(s) Detected - Logical drive configuration has automatically been updated 1726-Slot x Drive None Array - Array Accelerator Memory Size Change Detected 1727-Slot x Drive None Array - New Logical Drive(s) Attachment Detected. If more than 32 logical drives, this message will be followed by: Auto-configuration failed: Too many logical drives. 1730-Fixed Disk 0 None does not support DMA Mode. Probable Source of Problem The system has detected that the array enabler board is not installed. Incorrect cabling Recommended Action Install the array enabler board. Ensure that the integrated SCSI controller has the SCSI termination attached. Indicated drive has reported a SMART predictive-failure condition and may fail later. Logical drive configuration has been updated automatically after physical drive position changes. If the drive is part of a nonfault-tolerant configuration, back up all data before replacing the drive and restore all data afterward. If the drive is part of a fault-tolerant configuration do not replace it unless all other drives in the array are online. Press F1 to resume. Press F1 to resume. Array accelerator configuration has been updated automatically because the replacement of the array accelerator (or controller) with one with a different memory size. Controller has detected an additional array of drives that was attached when the power was off. The logical drive configuration information has been updated to add the new logical drives. The maximum number of logical drives supported is 32. Additional logical drives will not be added to the configuration. Hard drive error Press F1 to resume. Press F1 to resume. Run the System Configuration Utility and correct. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173

3-12
Compaq ProLiant 6400R Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
1622-Internal SCSI
Jumper Board Not
Installed
None
The system has detected that the
array enabler board is not
installed.
Install the array enabler board.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None
Incorrect cabling
Ensure that the integrated SCSI
controller has the SCSI
termination attached.
1720-Slot x Drive
Array
SMART Drive
Detects Imminent
Failure SCSI: Port y:
SCSI ID x
None
Indicated drive has reported a
SMART predictive-failure
condition and may fail later.
If the drive is part of a
nonfault-tolerant configuration,
back up all data before
replacing the drive and restore
all data afterward. If the drive is
part of a fault-tolerant
configuration
do not
replace it
unless all other drives in the
array are online. Press
F1
to
resume.
1724-Slot x Drive
Array
Physical
Drive Position
Change(s) Detected
Logical drive
configuration has
automatically been
updated
None
Logical drive configuration has
been updated automatically after
physical drive position changes.
Press
F1
to resume.
1726-Slot x Drive
Array
Array
Accelerator Memory
Size Change
Detected
None
Array accelerator configuration
has been updated automatically
because the replacement of the
array accelerator (or controller)
with one with a different memory
size.
Press
F1
to resume.
1727-Slot x Drive
Array
New Logical
Drive(s) Attachment
Detected. If more
than 32 logical
drives, this message
will be followed by:
Auto-configuration
failed: Too many
logical drives.
None
Controller has detected an
additional array of drives that
was attached when the power
was off. The logical drive
configuration information has
been updated to add the new
logical drives. The maximum
number of logical drives
supported is 32. Additional
logical drives will not be added to
the configuration.
Press
F1
to resume.
1730-Fixed Disk 0
does not support
DMA Mode.
None
Hard drive error
Run the System Configuration
Utility and correct.
continued