Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 104
Run the System Configuration Utility to initialize
View all Compaq ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 104 highlights
Diagnostics and Troubleshooting 3-37 Table 3-18 ADU Diagnostic Messages continued Message Description Drive (bay) X upload code not readable An error occurred while ADU tried to read the upload code information from the drive. Drive (bay) X was inadvertently replaced The physical drive was incorrectly replaced after another drive failed. Drive Monitoring features are unobtainable ADU unable to get monitor and performance data because of a fatal command problem, such as drive time-out, or unable to get data because these features are not supported on the controller. Drive Monitoring is NOT enabled for SCSI Port x Drive ID x The monitor and performance features have not been enabled on this drive. Drive time-out occurred on physical drive bay X ADU issued a command to a physical drive, but the command was never acknowledged. Drive X indicates position Y Message indicates a physical drive that appears to be scrambled or in a drive bay other than the one for which it was originally configured. Duplicate write memory error Error occurred reading RIS copy from SCSI Port x Drive ID x FYI: Drive (bay) X is non-Compaq supplied Data could not be written to the array accelerator board in duplicate because of the detection of parity errors. This is not a data-loss situation. An error occurred while ADU was tried to read the RIS from the drive. The installed drive was not supplied by Compaq. Recommended Action If there were multiple errors, the drive may need to be replaced. Replace the drive incorrectly replaced, and replace the original drive that failed. Do not run the System Configuration Utility and try to reconfigure. Data will be lost. Check for other errors (time-outs and so on). If no other errors occur, upgrade the firmware to a version that supports monitor and performance, if desired. Run the System Configuration Utility to initialize the monitor and performance features. The drive or cable may be bad. Check the other error messages on the Diagnostics screen to determine resolution. Examine the graphical drive representation on ADU to determine proper drive locations. Remove drive X and place it in drive position Y. Rearrange the drives according to the ADU instructions. Replace the array accelerator board. If there were multiple errors, the drive may need to be replaced. If problems exist with the drive, replace it with a Compaq drive. continued