Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 103
Run the System Configuration Utility to properly
View all Compaq ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
3-36 Compaq ProLiant 6400R Maintenance and Service Guide Table 3-18 ADU Diagnostic Messages continued Message Description Controller restarted with a signature of zero ADU did not find a valid configuration signature to use to get the data. Nonvolatile RAM may not be present (unconfigured), or the signature present in nonvolatile RAM may not match the signature on the controller. Disable command issued Posted writes have been disabled by the issuing of the Accelerator Disable command because of an operating system device driver. Drive (bay) X firmware needs upgrading Firmware on this physical drive is below the latest recommended version. Drive (bay) X has insufficient capacity for its configuration Drive has insufficient capacity to be used in this logical drive configuration. Drive (bay) X has invalid M&P stamp Physical drive has invalid monitor and performance data. Drive (bay) X has loose cable The array controller could not communicate with the drive at power-up. The drive has not previously failed. Drive (bay) X is a replacement drive Drive (bay) X is a replacement drive marked OK Drive (bay) X is failed Drive (bay) X is undergoing drive recovery Drive (bay) X needs replacing The drive has been replaced. The message displays if a drive is replaced in a fault-tolerant logical volume. The drive has been replaced and marked OK by the firmware. This may occur if a drive has an intermittent failure. For example, if a drive has previously failed, then when ADU is run, the drive starts working again. The indicated physical drive has failed. The drive is being rebuilt from the corresponding mirror or parity data. The 210-MB hard drive has firmware version 2.30 or 2.31. Recommended Action Run the System Configuration Utility to configure the controller and nonvolatile RAM. Restart the system. Run the ACU to reinitialize the array accelerator board. Run the Options ROMPaq Utility to upgrade the drive firmware to the latest revision. Replace the drive with a larger capacity drive. Run the System Configuration Utility to properly initialize this drive. Check all cable connections first. The cables could be bad, loose, or disconnected. Turn on the system, and attempt to reconnect the signal or power cable to the drive. If this does not work, replace the cable. If it does not work, the drive may need to be replaced. If the replacement was intentional, allow the drive to rebuild. Replace the drive. Replace the drive. Normal operations should occur. Replace the drive. continued