Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 93

Diskette Drive Test Error Codes

Page 93 highlights

3-26 Compaq ProLiant 6400R Maintenance and Service Guide 600 - 699, Diskette Drive Test Error Codes The 600 series of diagnostic error codes identifies failures with diskette, diskette drive, or system board functions. Table 3-8 Diskette Drive Test Error Codes Error Code 600-xx 601-xx 602-xx 603-xx 604-xx 605-xx 606-xx 607-xx 608-xx 609-xx 610-xx 694-xx 697-xx 698-xx 699-xx Description Diskette ID drive types test failed. Diskette format failed. Diskette read test failed. Diskette write, read, and compute test failed. Diskette random-seek test failed. Diskette ID media failed. Diskette speed test failed. Diskette wrap test failed. Diskette write-protect test failed. Diskette reset controller test failed. Diskette change line test failed. Pin 34 is not cut on 360-KB diskette drive. Diskette type error. Diskette drive speed not within limits. Diskette drive-media ID error. Recommended Action 1. Replace the diskette and retest. 2. Check and/or replace the diskette power and signal cables and retest. 3. Replace the diskette drive and retest. 4. Replace the system board and retest. 1. Replace the diskette and retest. 2. Check and/or replace the diskette power and signal cables and retest.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173

3-26
Compaq ProLiant 6400R Maintenance and Service Guide
600
699, Diskette Drive Test Error Codes
The 600 series of diagnostic error codes identifies failures with diskette, diskette drive, or
system board functions.
Table 3-8
Diskette Drive Test Error Codes
Error Code
Description
Recommended Action
600-xx
Diskette ID drive types test failed.
601-xx
Diskette format failed.
602-xx
Diskette read test failed.
603-xx
Diskette write, read, and compute
test failed.
604-xx
Diskette random-seek test failed.
605-xx
Diskette ID media failed.
606-xx
Diskette speed test failed.
607-xx
Diskette wrap test failed.
608-xx
Diskette write-protect test failed.
609-xx
Diskette reset controller test
failed.
610-xx
Diskette change line test failed.
694-xx
Pin 34 is not cut on
360-KB diskette drive.
697-xx
Diskette type error.
698-xx
Diskette drive speed not within
limits.
1.
Replace the diskette and retest.
2.
Check and/or replace the diskette power and
signal cables and retest.
3.
Replace the diskette drive and retest.
4.
Replace the system board and retest.
699-xx
Diskette drive-media ID error.
1.
Replace the diskette and retest.
2.
Check and/or replace the diskette power and
signal cables and retest.