Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 28

Hot-Plug Dual Redundant CPU Fan Assembly

Page 28 highlights

Removal and Replacement Procedures 2-11 Hot-Plug Dual Redundant CPU Fan Assembly CAUTION: If you must remove the hot-plug dual redundant CPU fan assembly while the server is powered up, you have 5 minutes to change it before shutdown (Windows NT, UNIX, and Novell NetWare). Removal of both fans will cause overheating and subsequent server shutdown. NOTE: An amber LED fan indicator indicates the fan has failed. If the LED indicator is green, the fan is working properly. See the section "Hot-Plug Fan LED Indicators" in Chapter 4. To remove the hot-plug, dual-redundant CPU fan assembly, 1. Remove the top access panel. See "Top Access Panel" earlier in this chapter. 2. Loosen the thumbscrew located at the top of the fan . 3. Lift the fan straight out of the chassis . 1 2 Figure 2-7. Removing the hot-plug, dual-redundant CPU fan assembly Reverse steps 1 through 3 to replace the hot-plug, dual-redundant CPU fan assembly. IMPORTANT: It is not necessary to turn off the server to replace hot-plug devices, such as power supplies, fans, or PCI Hot Plug boards.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173

Removal and Replacement Procedures
2-11
Hot-Plug Dual Redundant CPU Fan Assembly
CAUTION:
If you must remove the hot-plug dual redundant CPU fan assembly while the server
is powered up, you have 5 minutes to change it before shutdown (Windows NT, UNIX, and
Novell NetWare). Removal of both fans will cause overheating and subsequent server
shutdown.
NOTE:
An amber LED fan indicator indicates the fan has failed. If the LED indicator is green, the fan is
working properly. See the section “Hot-Plug Fan LED Indicators” in Chapter 4.
To remove the hot-plug, dual-redundant CPU fan assembly,
1.
Remove the top access panel. See “Top Access Panel” earlier in this chapter.
2.
Loosen the thumbscrew located at the top of the fan
.
3.
Lift the fan straight out of the chassis
.
1
2
Figure 2-7.
Removing the hot-plug, dual-redundant CPU fan assembly
Reverse steps 1 through 3 to replace the hot-plug, dual-redundant CPU fan assembly.
IMPORTANT:
It is not necessary to turn off the server to replace hot-plug devices, such as power
supplies, fans, or PCI Hot Plug boards.