3-18 Compaq ProLiant 6400R Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps 1786-Drive Array None Recovery Needed The following drive(s) need Automatic Data Recovery: Drive X. Select "F1" to continue with recovery of data to drive(s). Select "F2" to continue without recovery of data to drive(s). 1787-Drive Array None Operating in Interim Recovery Mode. Physical drive replacement needed: Drive X 1788-Incorrect Drive None Replaced: Drive X Drive(s) were incorrectly replaced: Drive Y Select "F1" to continue - drive array will remain disabled. Select "F2" to reset configuration - all data will be lost. 1789-Drive Not None Responding, Physical Drive Check cables or replace physical drive X. Select "F1" to continue - drive array will remain disabled. Select "F2" to fail drive(s) that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance. Probable Source of Problem Interim Data Recovery mode. Data have not been recovered yet. Recommended Action Press F1 to allow automatic data recovery to begin. Data will automatically be restored to drive X now that the drive has been replaced or seems to working. -or- Press F2. The system will continue to operate in the Interim Data Recovery mode. Hard drive X failed, or a cable is loose or defective. After a system restart, this message reminds you that drive X is defective and fault tolerance is being used. 1. Replace drive X as soon as possible. 2. Check loose cables. 3. Replace defective cables. Because the drives are not installed in their original positions, they have been disabled. See note below. Cable or hard drive failure Reinstall the drives correctly as indicated. Press F1 to restart the computer with the drive array disabled. -or- Press F2 to use the drives as configured and lose all the data on them. 1. Check the cable connections. 2. Replace the cables. 3. Replace the drive. If you do not want to replace the drive now, press F2. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173

3-18
Compaq ProLiant 6400R Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
1786-Drive Array
Recovery Needed
The following drive(s)
need Automatic Data
Recovery: Drive X.
Select "F1" to
continue with
recovery of data to
drive(s).
Select "F2" to
continue without
recovery of data to
drive(s).
None
Interim Data Recovery mode.
Data have not been recovered
yet.
Press
F1
to allow automatic
data recovery to begin. Data will
automatically be restored to
drive
X
now that the drive has
been replaced or seems to
working.
-or-
Press
F2.
The system will
continue to operate in the
Interim Data Recovery mode.
1787-Drive Array
Operating in Interim
Recovery Mode.
Physical drive
replacement needed:
Drive X
None
Hard drive
X
failed, or a cable is
loose or defective. After a system
restart, this message reminds
you that drive
X
is defective and
fault tolerance is being used.
1.
Replace drive X as soon as
possible.
2.
Check loose cables.
3.
Replace defective cables.
1788-Incorrect Drive
Replaced: Drive X
Drive(s) were
incorrectly replaced:
Drive Y Select "F1"
to continue - drive
array will remain
disabled. Select "F2"
to reset configuration
- all data will be lost.
None
Because the drives are not
installed in their original
positions, they have been
disabled.
See
note below.
Reinstall the drives correctly as
indicated.
Press
F1
to restart the computer
with the drive array disabled.
-or-
Press
F2
to use the drives as
configured and lose all the data
on them.
1789-Drive Not
Responding, Physical
Drive
Check cables or
replace physical
drive X.
Select "F1" to
continue - drive array
will remain disabled.
Select "F2" to fail
drive(s) that are not
responding -
Interim Recovery
Mode will be enabled
if configured for fault
tolerance.
None
Cable or hard drive failure
1.
Check the cable
connections.
2.
Replace the cables.
3.
Replace the drive. If you
do not want to replace the
drive now, press
F2
.
continued