Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 74
Error Messages of the Power-On Self-Test
View all Compaq ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
Diagnostics and Troubleshooting 3-7 Error Messages of the Power-On Self-Test An error in the system found by the POST is indicated by an audible or visual message. If an error code displays on the screen during POST or after a reset of the system, use the instructions in Table 3-2. NOTE: Many of the actions in Table 3-2 require you to run Diagnostics or the Compaq System Configuration Utility. The steps for running the utilities are after Table 3-2. In Table 3-2, the Recommended Action column lists the steps necessary to correct the error. After completing each step, run the Diagnostics program to verify whether the error has been corrected. If the error code reappears, perform the next step, and then re-run the Diagnostics program. Follow this procedure until Diagnostics no longer detects an error. Error Code A Critical Error occurred prior to this power-up Unsupported Processor Detected System Halted FATAL ROM ERROR: The System ROM is not properly programmed 101-ROM Error 101-I/O ROM Error 102-System Board Failure 104-ASR-2 Timer Failure 105-Current System ROM is corrupt - now booting redundant System ROM 162-System Options Not Set 163-Time & Date Not Set Table 3-2 POST Error Messages Audible Beeps None 1 long, 1 short 1 long, 1 short Probable Source of Error A catastrophic system error, which caused the server to crash has been logged. Processor not supported by current system ROM. ROM was programmed in the factory incorrectly. Recommended Action Run Diagnostics. Replace the failed assembly as indicated. Check documentation for supported processors, and, if supported, remove the processor and update the system to latest ROM. Replace the physical ROM part. 1 long, 1 short None None None 2 long System ROM checksum Options ROM checksum Direct Memory Access (DMA) timers, and so on System board failure Nonbooted ROM image is corrupt. Run Diagnostics. Replace the failed assembly as indicated. Run Diagnostics. Replace the failed assembly as indicated. Replace the system board. Run the Compaq System Configuration Utility. Run Diagnostics. Replace the failed assembly as indicated. Flash the ROM utilizing ROMPaq. 2 short 2 short Incorrect configuration Invalid time or date in configuration memory Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. continued