Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 126

Revision History Table

Page 126 highlights

Diagnostics and Troubleshooting 3-59 Table 3-23 ASR-2 IML or Critical Error Log Messages continued Message Description NMI - Processor Parity Error The processor detected a data error, resulting in a server failure. Server Manager Failure An error occurred with the Server Manager/R. NMI - Software Generated Interrupt Detected Error Software indicated a system error, resulting in a server failure. Caution: Temperature Exceeded The operating system has detected that the temperature of the system has exceeded the caution level. Accompanying data in the log notes whether an autoshutdown sequence has been invoked by the operating system. Abnormal Program Termination The operating system has encountered an abnormal situation that has caused a system failure. ASR-2 Test Event The System Configuration Utility generated a test alert. NMI - Automatic Server Recovery Timer Expiration The operating system has received notice of an impending ASR-2 timer expiration. Required System Fan Failure The required system fan has failed. Accompanying data in the log notes if an auto-shutdown sequence has been invoked by the operating system. UPS A/C Line Failure Shutdown or Battery Low The UPS notified the operating system that the AC power line has failed. Accompanying data indicates whether either an auto-shutdown sequence has been invoked or the battery is nearly depleted. ASR-2 detected by ROM An ASR-2 activity has been detected and logged by the system ROM. Revision History Table Some errors can be resolved by reviewing changes to the server configuration. The server has an Automatic Revision Tracking (ART) feature that helps you review recent changes to the server configuration. One ART feature is the Revision History Table, which contains the hardware version number of the system board and any other system boards providing ART-compatible revision information. The feature lets you determine the level of functioning of an assembly in a system without opening or powering down the unit.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173

Diagnostics and Troubleshooting
3-59
Table 3-23
ASR-2 IML or Critical Error Log Messages
continued
Message
Description
NMI - Processor Parity Error
The processor detected a data error, resulting in a server failure.
Server Manager Failure
An error occurred with the Server Manager/R.
NMI - Software Generated
Interrupt Detected Error
Software indicated a system error, resulting in a server failure.
Caution: Temperature Exceeded
The operating system has detected that the temperature of the system has
exceeded the caution level. Accompanying data in the log notes whether
an autoshutdown sequence has been invoked by the operating system.
Abnormal Program Termination
The operating system has encountered an abnormal situation that has
caused a system failure.
ASR-2 Test Event
The System Configuration Utility generated a test alert.
NMI - Automatic Server
Recovery Timer Expiration
The operating system has received notice of an impending ASR-2 timer
expiration.
Required System Fan Failure
The required system fan has failed. Accompanying data in the log notes if
an auto-shutdown sequence has been invoked by the operating system.
UPS A/C Line Failure Shutdown
or Battery Low
The UPS notified the operating system that the AC power line has failed.
Accompanying data indicates whether either an auto-shutdown sequence
has been invoked or the battery is nearly depleted.
ASR-2 detected by ROM
An ASR-2 activity has been detected and logged by the system ROM.
Revision History Table
Some errors can be resolved by reviewing changes to the server configuration. The server has an
Automatic Revision Tracking (ART) feature that helps you review recent changes to the server
configuration.
One ART feature is the Revision History Table, which contains the hardware version number of
the system board and any other system boards providing ART-compatible revision information.
The feature lets you determine the level of functioning of an assembly in a system without
opening or powering down the unit.