LG PQCPA11A0E Owner's Manual - Page 23
Setting address with wired remote controller
View all LG PQCPA11A0E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
2. Installing ACP Setting address with wired remote controller AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED SUB FUNCTION HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE 1234 Timer Operation unit Program set On Off Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23 Program Timer Cancel Program Week Holiday Set/Clr Plasma Hour Min RESET Set/Ctl 1. Press Week Program & Set/Clr keys at the same time. 2. Set the indoor unit address using the temperature controller. Allowed Range : 00-FF EX) 3 A Group No. Indoor Unit No. 3. Complete the address setting to press the week Program & Set/Clr keys at the same time for 3 seconds. ❈ Some remote controllers may not be suported by above functions, a coording to the production date of wired/wireless remote conrollers. As it has no concem with customers' use, use the remote controller available for the address setting during installation. Installation/Owner's Manual 2-9