LG PQCPA11A0E Owner's Manual - Page 79

Enter and modify the ventilator group, name and the ventilator information., However, we recommend

Page 79 highlights

2. Installing ACP 8. Enter the ventilator group name and the information of the ventilator. When each displayed item is clicked, it's color is changed to yellow for its contents to be directly entered or the list box is displayed. Enter the setting value suitable for each item. See the following table for the description on the setting item. Enter and modify the ventilator group name and the ventilator information. However, we recommend to use 'Physical address' item as set. Item Group name Type Ventilator name Physical address Model name Maximum consumed power Description Enter the ventilator group name for the user to easily recognize. Leave this information as it is without changing. Enter the ventilator name for the user to easily recognize. Enter the physical address of the ventilator. When [Default input] button is pressed, it is automatically created by inheriting the higher information. Physical address is composed of 4 numbers. The first and second number is the G/W number and ventilator group number, respectively. This can be set only within the entered information from existing [G/W information] and [Ventilator group input] menu. The third number is the ventilator number, which cannot be duplicated within the same ventilator group number and must be set within the range of 0~15. The fourth number is the Master and Slave setting. This value is set to 0 (Master) and must not be changed. Enter the model name of the ventilator. Enter the maximum consumed power for the ventilator to use. The maximum consumed power depends on the model. Installation/Owner's Manual 2-65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

2. Installing ACP
Installation/Owner's Manual
2-65
8.
Enter the ventilator group name and the information of the ventilator. When each displayed item is
clicked, it's color is changed to yellow for its contents to be directly entered or the list box is
displayed. Enter the setting value suitable for each item. See the following table for the description
on the setting item.
Item
Description
Group name
Enter the ventilator group name for the user to easily recognize.
Type
Leave this information as it is without changing.
Ventilator name
Enter the ventilator name for the user to easily recognize.
Physical address
Enter the physical address of the ventilator. When [Default input]
button is pressed, it is automatically created by inheriting the higher
information.
Physical address is composed of 4 numbers.
The first and second number is the G/W number and ventilator group
number, respectively. This can be set only within the entered
information from existing [G/W information] and [Ventilator group input]
menu. The third number is the ventilator number, which cannot be
duplicated within the same ventilator group number and must be set
within the
range of 0~15. The fourth number is the Master and Slave
setting.
This value is set to 0 (Master) and must not be changed.
Model name
Enter the model name of the ventilator.
Maximum consumed power
Enter the maximum consumed power for the ventilator to use. The
maximum consumed power depends on the model.
Enter and modify the ventilator group
name and the ventilator information.
However, we recommend to use
'Physical address' item as set.