LG PQCPA11A0E Owner's Manual - Page 47

Setting the functions of the ACP

Page 47 highlights

Setting the functions of the ACP The following functions can be set by using the menu of the ACP: • Select Peak or Demand • Select the web display language • Set the schedule to use • Set the wattage display to use 2. Installing ACP Before setting the functions of the ACP The function setting of the ACP should be changed depending on the case that only the ACP is used or the case that the ACP is interconnected with the external devices such as AC Manager, Wattmeter and Demand controller. In general, the function of the ACP should be set and used as follows: ACP only ACP interconnected with AC Manager ACP interconnected with Demand controller Select Peak or Demand Schedule Wattage display Set to Peak function Set to Demand function Set the schedule function to use Set the schedule function not to use Set to Demand function Set the schedule function to use Set to use if interconnected woth the wattmeter or set not to use if not. Caution: Setting the wattage display to use If the ACP and the wattmeter are not connected, the wattage display function should be set not to use. If it is set to use, be careful of it because the control speed of the ACP is getting slow. Installation/Owner's Manual 2-33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

Installation/Owner's Manual
2-33
2. Installing ACP
Setting the functions of the ACP
The following functions can be set by using the menu of the ACP:
Select Peak or Demand
Select the web display language
Set the schedule to use
Set the wattage display to use
The function setting of the ACP should be changed depending on the case that only the ACP is used
or the case that the ACP is interconnected with the external devices such as AC Manager, Wattmeter
and Demand controller.
In general, the function of the ACP should be set and used as follows:
Before setting the functions of the ACP
ACP only
ACP interconnected
with AC Manager
ACP interconnected
with Demand controller
Set to Peak function
Set to Demand function
Set to Demand
function
Set the schedule
Set the schedule
Set the schedule
function to use
function not to use
function to use
Set to use if interconnected woth the wattmeter or set not to use if not.
Select Peak or Demand
Schedule
Wattage display
Caution: Setting the wattage display to use
If the ACP and the wattmeter are not connected, the wattage display function should
be set not to use. If it is set to use, be careful of it because the control speed of the
ACP is getting slow.