Linksys SGE2000 Cisco Small Business SFE/SGE2xxx Series Managed Switches Admin - Page 394
Modifying RMON Alarm Settings, Events Rising Alarm, Falling Alarm, Rising and Falling
UPC - 745883572120
View all Linksys SGE2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 394 highlights
Viewing Statistics Configuring RMON History 17 • Falling Threshold - Displays the falling counter value that triggers the falling threshold alarm. The falling threshold is graphically presented on top of the graph bars. Each monitored variable is designated a color. • Falling Event - Selects an event which is defined in the Events table that triggers the falling threshold alarm. The Events Table is displayed in the RMON Events Page. • Startup Alarm - Displays the trigger that activates the alarm generation. Rising is defined by crossing the threshold from a low-value threshold to a higher-value threshold. - Rising Alarm - The rising counter value that triggers the rising threshold alarm. - Falling Alarm - The falling counter value that triggers the falling threshold alarm. - Rising and Falling - The rising and falling counter values that trigger the alarm. • Interval - Defines the alarm interval time in seconds. • Owner - Displays the device or user that defined the alarm. STEP 3 Define the relevant fields. STEP 4 Click Apply. The RMON alarm is added, and the device is updated. Modifying RMON Alarm Settings STEP 1 Click Statistics > RMON > Alarms. The RMON Alarms Page opens: STEP 2 Click the Edit Button. The Edit RMON Alarm Page opens: Cisco Small Business SFE/SGE Managed Switches Administration Guide 385