Oki ML591 Users' Guide for the OkiLAN 6010e - Page 151
Appendix A: Troubleshooting, Main Status Indicator, Restoring the OkiLAN 6010e to Factory Defaults
View all Oki ML591 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 151 highlights
Section IV - TCP/IP Appendix A: Troubleshooting Main Status Indicator Upon power-up, the main status indicator flashes orange. It changes to green when the OkiLAN 6010e passes self-test. The indicator stays orange if the OkiLAN 6010e fails self-test. If the indicator turns solid orange due to an error, a configuration sheet will be printed automatically. Check the error message reported on the configuration sheet. Restoring the OkiLAN 6010e to Factory Defaults In most cases, the best way to restore the OkiLAN 6010e to factory defaults is via telnet. However, if you are unable to connect to the device because of a configuration error, use the following method which does not require a network connection. To restore the OkiLAN 6010e to factory defaults, complete the following steps: 1. Power down the OkiLAN 6010e. 2. While holding in the Print Configuration Sheet Test button, power up the OkiLAN 6010e. Hold the button until the status indicator turns solid green. 3. Power cycle the OkiLAN 6010e. It will have restored itself to defaults. OKI OkiLAN 6010e User's Guide IV - 61 TCP/IP