Panasonic HPX300 Operating Instructions - Page 112

To set whether or not the uploaded, metadata is recorded, Selecting the USER CLIP NAME recording

Page 112 highlights

Chapter 6 Manipulating Clips with Thumbnails 3 Use the cursor buttons to move the pointer to the item to confirm and press the SET button. • Use this function to check loaded metadata settings. Selecting the USER CLIP NAME recording method Select META DATA  USER CLIP NAME from the thumbnail menu to select the recording method. Two options are available: TYPE1 and TYPE2. TYPE1(Factory defaults) USER CLIP NAME to be recorded If clip metadata has been read in Uploaded data If no clip metadata has been read in or if the setting for recording clip metadata has been turned off Same as GLOBAL CLIP ID (UMID data) TYPE2 USER CLIP NAME to be recorded 4 While viewing metadata settings, use the cursor buttons to move the pointer to the desired option. Then, press the SET button. • A soft keyboard screen is displayed, allowing you to modify the setting. If clip metadata has been read in If no clip metadata has been read in or if the setting for recording clip metadata has been turned off Uploaded data + COUNT value*1 Same as CLIP NAME *1 The COUNT value is indicated as a four-digit number. The COUNT value is incremented each time a new clip is captured if clip metadata has been read in and TYPE2 has been selected as the recording method. The COUNT value can be reset using the following procedure. Select META DATA  PROPERTY from the thumbnail menu, then select USER CLIP NAME to display the menu shown below. Select "COUNT RESET" with the cursor and press the SET button to reset the COUNT value to 1. To set whether or not the uploaded metadata is recorded Set "ON"/"OFF" in META DATA  RECORD from the thumbnail menu. The factory setting is "OFF". 112  NOTE When an 8 GB or larger capacity P2 is used and the recording session exceeds the prescribed duration (DVCPRO HD and the AVCIntra100: about 5 minutes; AVC-Intra50: about 10 minutes) or spans more than one P2 card, the recording will automatically be split into separate clips. At this time, each clip will be provided with its own COUNT value.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

11±
Chapter²¶² Manipulating²Clips²with²Thumbnails
3
²
Use²the²cursor²buttons²to²move²the²pointer²to²
the²item²to²confirm²and²press²the²SET²button.
• Use this function to check loaded metadata
settings.
4
²
While²viewing²metadata²settings,²use²the²cursor²
buttons²to²move²the²pointer²to²the²desired²
option.²Then,²press²the²SET²button.²
• A soft keyboard screen is displayed, allowing you
to modify the setting.
To set whether or not the uploaded
metadata is recorded
Set “ON”/“OFF” in META DATA
RECORD from the
thumbnail menu. The factory setting is “OFF”.
Selecting the USER CLIP NAME recording
method
Select META DATA
USER CLIP NAME from the thumbnail
menu to select the recording method. Two options are
available: TYPE1 and TYPE2.
TYPE1(Factory²defaults)
USER CLIP NAME to be
recorded
If clip metadata has been
read in
Uploaded data
If no clip metadata has been
read in or if the setting for
recording clip metadata has
been turned off
Same as GLOBAL CLIP ID
(UMID data)
TYPE±
USER CLIP NAME to be
recorded
If clip metadata has been
read in
Uploaded data + COUNT
value
*1
If no clip metadata has been
read in or if the setting for
recording clip metadata has
been turned off
Same as CLIP NAME
*1 The COUNT value is indicated as a four-digit number.
The COUNT value is incremented each time a new clip
is captured if clip metadata has been read in and TYPE2
has been selected as the recording method.
The COUNT value can be reset using the following
procedure.
Select META DATA
PROPERTY from the thumbnail
menu, then select USER CLIP NAME to display the
menu shown below. Select “COUNT RESET” with the
cursor and press the SET button to reset the COUNT
value to 1.
NOTE
When an 8 GB or larger capacity P2 is used and the recording
session exceeds the prescribed duration (DVCPRO HD and
the AVCIntra100: about 5 minutes; AVC-Intra50: about 10
minutes) or spans more than one P2 card, the recording will
automatically be split into separate clips. At this time, each clip
will be provided with its own COUNT value.