Panasonic HPX300 Operating Instructions - Page 99
DC OUT Connector and External REC Start/Stop Switch Connection
UPC - 791871304297
View all Panasonic HPX300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
DC OUT Connector and External REC Start/Stop Switch Connection The DC OUT connector on the camera can output a 1.5 A current. Connecting an external switch to this connector enables REC Start and Stop control. An LED can be connected and used as a tally lamp, which is convenient when the camera is mounted on a crane during recording. Chapter 5 Preparation (Connection example) 41 32 DC OUT connector Cable connector HR10A-7P-4P(73) Hirose Electric Co. (For details on connecting the connector, refer to page 164.) LED Resist ance REC Start/Stop 1: GND 2: TALLY OUT The AG-HPX300P has open collector output TALLY ON: Low impedance TALLY OFF: High impedance 3: REC Start/Stop switch This pin is connected in parallel with the REC button and the lens VTR button. 4: +12 V NOTE: Be sure to check polarity before connecting an external device as incorrect connection could lead to damage. 99