Panasonic HPX300 Operating Instructions - Page 137

Other Functions Screen, Setting, Notes, Load, Save, Initial, Chain, Rec_p, On, Off, High, Low, Hd Sdi

Page 137 highlights

Chapter 7 Menu Operations OTHER FUNCTIONS screen Item USER FILE 1394 CONTROL 1394 CMD SEL ACCESS LED ALARM CLOCK SETTING TIME ZONE GL PHASE H PHASE MENU INIT Setting Notes Saves user files to camera memory, loads them into • N ot available when PC MODE SELECT camera memory or initializes them. (For details, refer is set to USB DEVICE and PC MODE to page 80.) is set to ON. LOAD, SAVE, INITIAL • This does not affect options in the SCENE FILE screen. Selects the method the camera uses for controlling • Not available in AVC-Intra mode and external devices connected to the DVCPRO/DV DVCPRO HD native mode. connector. (For details, refer to page 145.) • Not available during interval, one-shot EXT: Controls only the external device, but does not and loop recording. transfer data to the camera for recording. BOTH: Controls both the external device and the camera, and also records. CHAIN: When there is no more space left for recording in the camera, recording is automatically made to the external device. OFF: No control Determines how recording is stopped when the • Not available in AVC-Intra mode and camera controls an external device connected to the DVCPRO HD native mode. DVCPRO/DV connector. • Not available during interval, one-shot REC_P: Engages REC/PAUSE status. and loop recording. STOP: Stops recording. Determines whether or not the P2 CARD ACCESS LED should light. ON, OFF Sets the alarm sound output when an alarm occurs. HIGH, LOW, OFF Sets the internal calendar (date) For details, see [Setting Date and Time of Internal Clock] (page 26). Sets the time difference relative to Greenwich Mean • This setting cannot be initialized by Time (GMT). performing the MENU INIT option and -12:00 ... 0:00 ... +13:00 the INITIAL option in USER FILE. For details, see [Setting Date and Time of Internal Clock] (page 26). Selects the output signal whose phase is locked to • Not available when SYSTEM MODE is the signal input to the GENLOCK IN connector in HD set to 480-59.94i. (1080i, 720P) mode. (For details, refer to page 64.) HD SDI: The HD SDI is locked to the genlock input. COMPOSITE: The down-converted composite signal (VIDEO OUT or SDI OUT 480i signal) is locked to the genlock input. Adjusts the horizontal phase when phase is locked to • Hold down the JOG dial button and the signal input to the GENLOCK IN connector. turn it downwards or upwards and -512 ... 0 ... +511 maintain this position to quickly change values. Restores all setting menu values including all scene • Not available when PC MODE SELECT files F1 to F6 and the user file to their factory defaults. is set to USB DEVICE and PC MODE is set to ON. ____ indicates the factory setting 137

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

1³·
Chapter²·² Menu²Operations
OTHER FUNCTIONS screen
Item
Setting
Notes
USER FILE
Saves user files to camera memory, loads them into
camera memory or initializes them. (For details, refer
to page 80.)
LOAD, SAVE, INITIAL
• This does not affect options in the SCENE FILE
screen.
• Not available when PC MODE SELECT
is set to USB DEVICE and PC MODE
is set to ON.
1394 CONTROL
Selects the method the camera uses for controlling
external devices connected to the DVCPRO/DV
connector. (For details, refer to page 145.)
EXT:
Controls only the external device, but does not
transfer data to the camera for recording.
BOTH:
Controls both the external device and the
camera, and also records.
CHAIN:
When there is no more space left for recording
in the camera, recording is automatically made to the
external device.
OFF:
No control
• Not available in AVC-Intra mode and
DVCPRO HD native mode.
• Not available during interval, one-shot
and loop recording.
1394 CMD SEL
Determines how recording is stopped when the
camera controls an external device connected to the
DVCPRO/DV connector.
REC_P:
Engages REC/PAUSE status.
STOP:
Stops recording.
• Not available in AVC-Intra mode and
DVCPRO HD native mode.
• Not available during interval, one-shot
and loop recording.
ACCESS LED
Determines whether or not the P2 CARD ACCESS LED
should light.
ON, OFF
ALARM
Sets the alarm sound output when an alarm occurs.
HIGH, LOW, OFF
CLOCK SETTING
Sets the internal calendar (date)
For details, see [Setting Date and Time of Internal
Clock] (page 26).
TIME ZONE
Sets the time difference relative to Greenwich Mean
Time (GMT).
–12:00 ... 0:00 ... +13:00
For details, see [Setting Date and Time of Internal
Clock] (page 26).
• This setting cannot be initialized by
performing the MENU INIT option and
the INITIAL option in USER FILE.
GL PHASE
Selects the output signal whose phase is locked to
the signal input to the GENLOCK IN connector in HD
(1080i, 720P) mode. (For details, refer to page 64.)
HD SDI:
The HD SDI is locked to the genlock input.
COMPOSITE:
The down-converted composite signal
(VIDEO OUT or SDI OUT 480i signal) is locked to the
genlock input.
• Not available when SYSTEM MODE is
set to 480-59.94i.
H PHASE
Adjusts the horizontal phase when phase is locked to
the signal input to the GENLOCK IN connector.
–512 ... 0 ... +511
• Hold down the JOG dial button and
turn it downwards or upwards and
maintain this position to quickly
change values.
MENU INIT
Restores all setting menu values including all scene
files F1 to F6 and the user file to their factory defaults.
• Not available when PC MODE SELECT
is set to USB DEVICE and PC MODE
is set to ON.
____ indicates the factory setting