Panasonic WVCU650 Operating Instructions - Page 19

SETUP PROCEDURES (FIRMWARE), Administrator Password Entry, Setting Modes

Page 19 highlights

SETUP PROCEDURES (FIRMWARE) ■ Administrator Password Entry If you log into the system in the administrator mode, PS·Data communication setting, all reset, operator password check. and database copy will become available. To activate the administrator mode, you need to enter the administrator password. Notes: • The factory default of administrator password is "650". However, for security, you should change the password setting. To change the setting, refer to p. 24. • Take a note of your administrator password. ■ Setting Modes If you power on the system controller while pressing the following buttons, the system will run in an associated setting mode. Notes: • You cannot change the system from the following modes (refer to the diagram) to the normal operation mode. To start up the normal operation mode, turn off the system controller, and then turn on the controller again. • The administrator password entry is required for the following modes. Buttons pressed while the power-on 2, 4, and 6 Setting Mode All reset MON (ESC) and 6 MON (ESC) and 1 PS·Data Communication setting Administrator password change Description The communication settings and PS·Data database can be restored to the factory default.* PS·Data communication setting can be performed. The administrator password can be changed. MON (ESC) and 2 PS·Data database copy The PS·Data database can be copied from the source system controller (Controller No. 1) to a destination system controller. MON (ESC) and 4 PS·Data password display The passwords of up to 16 operators can be displayed on the LCD. * The panning, tilting, and zooming calibration settings are not restored. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

19
SETUP PROCEDURES (FIRMWARE)
Administrator Password Entry
If you log into the system in the administrator mode,
PS·Data communication setting, all reset, operator pass-
word check. and database copy will become available.
To activate the administrator mode, you need to enter the
administrator password.
Notes:
• The factory default of administrator password is “650”.
However, for security, you should change the password
setting. To change the setting, refer to p. 24.
Take a note of your administrator password.
Setting Modes
If you power on the system controller while pressing the fol-
lowing buttons, the system will run in an associated setting
mode.
Notes:
• You cannot change the system from the following
modes (refer to the diagram) to the normal operation
mode. To start up the normal operation mode, turn off
the system controller, and then turn on the controller
again.
The administrator password entry is required for the fol-
lowing modes.
* The panning, tilting, and zooming calibration settings are
not restored.
Buttons pressed
while
the power-on
2, 4, and 6
MON (ESC) and 6
MON (ESC) and 1
Administrator
password change
The administrator
password can be
changed.
Setting Mode
All reset
PS·Data
Communication
setting
Description
The communication
settings and
PS·Data database
can be restored to
the factory default.*
PS·Data communi-
cation setting can
be performed.
MON (ESC) and 2
MON (ESC) and 4
PS·Data database
copy
PS·Data password
display
The PS·Data data-
base can be copied
from the source
system controller
(Controller No. 1) to
a destination sys-
tem controller.
The passwords of
up to 16 operators
can be displayed
on the LCD.