Panasonic WVCU650 Operating Instructions - Page 29

Operation Start (Login), Login OK, Mon04 Cam128, Unit16, HD316, Invalid, PS Data Mode, No User

Page 29 highlights

● Button Buzzer Setting You will perform the setting whether to activate a sound when a button is pressed. Select the desired parameter by rotating the JogDial. Buzzer Operation ON User ID __650 Notes: • To delete a character, press the CLEAR button. • You can also enter your user ID without pressing the CAM (SET) button. Notes: • OFF or ON is selectable. The factory default is ON. • If set to ON, short buzzer will sound three times in the following occasions. (p. 15) Invalid, Prohibited (p. 62) Level 1 Fixed ■ Operation Start (Login) Before starting operation, user authentication by the ID and password is required. (Refer to p. 62 for details on the setting of ID and password.) Notes: • User authentication is skipped when the auto login is set to ON. (Refer to p. 30.) • The factory default of operator information is as follows. • If no operation has been performed for 5 seconds or more, the LCD display will return to the login standby display. 5. Press the CAM (SET) button. When the ID number is correct, "Password" entry form appears on the LCD. User ID Password 650 _____ 6. Enter the password by pressing the numeric buttons. Then, press the CAM (SET) button. User ID Password 650 Notes: • To delete a character, press the CLEAR button. • The password will be displayed as ∗ marks. 7. When the password is correct, "Login OK" appears on the LCD. Then, the LCD changes to the operation display. Operator No. User ID 1 650 2 1 3 100 4 101 5 102 6 103 Password 650 12345 100 101 102 103 Function level Camera level 1 1 1 1 2 1 3 1 3 1 3 1 1. Turn on the power. (Refer to p. 27 Power-on and Poweroff.) 2. Wait until the login standby display appears. PS·Data Mode No User 3. Press the CAM (SET) button. "User ID" entry form will appear on the LCD. User ID _____ Login OK Mon04 Cam128 Unit16 F1 F2 F3 F4 Mon04 Cam128 HD316 F1 F2 F3 F4 Notes: • The smallest monitor, camera, and unit numbers are displayed on the LCD. • Three seconds after the unit number was determined, model number appears in place of unit number. • When the ID or password is wrong, "Invalid" blinks on the LCD. Then, the LCD returns to the login standby display. Invalid 4. Enter the ID number by pressing the numeric buttons. The user ID entered will appear on the LCD. PS • Data Mode No User 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

29
Button Buzzer Setting
You will perform the setting whether to activate a sound
when a button is pressed. Select the desired parameter by
rotating the JogDial.
Notes:
OFF or ON is selectable. The factory default is ON.
• If set to ON, short buzzer will sound three times in the
following occasions.
(p. 15) Invalid, Prohibited
(p. 62) Level 1 Fixed
Operation Start (Login)
Before starting operation, user authentication by the ID and
password is required. (Refer to p. 62 for details on the set-
ting of ID and password.)
Notes:
• User authentication is skipped when the auto login is
set to ON. (Refer to p. 30.)
The factory default of operator information is as follows.
• If no operation has been performed for 5 seconds or
more, the LCD display will return to the login standby
display.
1.
Turn on the power. (Refer to p. 27 Power-on and Power-
off.)
2.
Wait until the login standby display appears.
3. Press the CAM (SET) button. “User ID” entry form will
appear on the LCD.
4. Enter the ID number by pressing the numeric buttons.
The user ID entered will appear on the LCD.
Notes:
To delete a character, press the CLEAR button.
• You can also enter your user ID without pressing the
CAM (SET) button.
5. Press the CAM (SET) button. When the ID number is
correct, “Password” entry form appears on the LCD.
6. Enter the password by pressing the numeric buttons.
Then, press the CAM (SET) button.
Notes:
To delete a character, press the CLEAR button.
The password will be displayed as
marks.
7. When the password is correct, “Login OK” appears on
the LCD. Then, the LCD changes to the operation dis-
play.
Notes:
The smallest monitor, camera, and unit numbers are
displayed on the LCD.
• Three seconds after the unit number was deter-
mined, model number appears in place of unit num-
ber.
• When the ID or password is wrong, “Invalid” blinks
on the LCD. Then, the LCD returns to the login
standby display.
Login OK
Mon04 Cam128
Unit16
F1
F2
F3
F4
Mon04 Cam128
HD316
F1
F2
F3
F4
Invalid
PS Data Mode
No User
Buzzer Operation
ON
Operator No.
User ID
Password
Function level
Camera level
1
650
650
1
1
2
1
12345
1
1
3
100
100
2
1
4
101
101
3
1
5
102
102
3
1
6
103
103
3
1
User ID
_____
User ID
650
Password
_____
User ID
650
Password
__
∗∗∗
PS·Data Mode
No User
User ID
__650