Panasonic WVCU650 Operating Instructions - Page 22

Wait Time Setting, Parity Bit Setting, Stop Bit Setting, PS Data Com. Setup, Stop Bit 2, Wait Time Off

Page 22 highlights

4. Press the MON (ESC) button. The selected parameter will be determined, and the LCD display will return from the editing mode to the display mode. PS • Data Com. Setup Baud Rate 4800 3. Select a desired parameter by rotating the JogDial or pressing the + or - button. You can select the desired parameter from "1" (bit) and "2". The factory default is "1". PS • Data Com. Setup Stop Bit 2 ● Parity Bit Setting 1. Select "Parity Bit" by rotating the JogDial. (Refer to Step 5 in p. 21.) 2. Press the CAM (SET) button. The LCD display will change from the display mode to the editing mode. PS • Data Com. Setup Parity Bit None 3. Select a desired parameter by rotating the JogDial or pressing the + or - button. You can select the desired parameter from "None", "Odd", and "Even". The factory default is "None". PS • Data Com. Setup Parity Bit Even 4. Press the MON (ESC) button. The selected parameter will be determined, and the LCD display will return from the editing mode to the display mode. PS • Data Com. Setup Parity Bit Even ● Stop Bit Setting 1. Select "Stop Bit" by rotating the JogDial. (Refer to Step 5 in p. 21.) 2. Press the CAM (SET) button. The LCD display will change from the display mode to the editing mode. PS • Data Com. Setup Stop Bit 1 4. Press the MON (ESC) button. The selected parameter will be determined, and the LCD display will return from the editing mode to the display mode. PS • Data Com. Setup Stop Bit 2 ● Wait Time Setting 1. Select "Wait Time" by rotating the JogDial. (Refer to Step 5 in p. 21.) 2. Press the CAM (SET) button. The LCD display will change from the display mode to the editing mode. PS • Data Com. Setup Wait Time Off 3. Select a desired parameter by rotating the JogDial or pressing the + or - button. You can select the desired parameter from "Off", "100 (msec)", "200", "400", and "1000". PS • Data Com. Setup Wait Time 100 4. Press the MON (ESC) button. The LCD display will return from the editing mode to the display mode, and the selected parameter will be determined. PS • Data Com. Setup Wait Time 100 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

22
3. Select a desired parameter by rotating the JogDial
or pressing the + or – button.
You can select the desired parameter from “1” (bit) and
“2”. The factory default is “1”.
4.
Press the MON (ESC) button.
The selected parameter will be determined, and the
LCD display will return from the editing mode to the dis-
play mode.
Wait Time Setting
1.
Select “Wait Time” by rotating the JogDial.
(Refer to Step 5 in p. 21.)
2.
Press the CAM (SET) button.
The LCD display will change from the display mode to
the editing mode.
3. Select a desired parameter by rotating the JogDial
or pressing the + or – button.
You can select the desired parameter from “Off”, “100
(msec)”, “200”, “400”, and “1000”.
4.
Press the MON (ESC) button.
The LCD display will return from the editing mode to the
display mode, and the selected parameter will be
determined.
4.
Press the MON (ESC) button.
The selected parameter will be determined, and the
LCD display will return from the editing mode to the dis-
play mode.
Parity Bit Setting
1.
Select “Parity Bit” by rotating the JogDial.
(Refer to Step 5 in p. 21.)
2.
Press the CAM (SET) button.
The LCD display will change from the display mode to
the editing mode.
3. Select a desired parameter by rotating the JogDial
or pressing the + or – button.
You can select the desired parameter from “None”,
“Odd”, and “Even”. The factory default is “None”.
4.
Press the MON (ESC) button.
The selected parameter will be determined, and the
LCD display will return from the editing mode to the dis-
play mode.
Stop Bit Setting
1.
Select “Stop Bit” by rotating the JogDial.
(Refer to Step 5 in p. 21.)
2.
Press the CAM (SET) button.
The LCD display will change from the display mode to
the editing mode.
PS Data Com. Setup
Stop Bit 2
PS Data Com. Setup
Wait Time Off
PS Data Com. Setup
Wait Time 100
PS Data Com. Setup
Stop Bit 1
PS Data Com. Setup
Baud Rate 4800
PS Data Com. Setup
Stop Bit 2
PS Data Com. Setup
Parity Bit None
PS Data Com. Setup
Parity Bit Even
PS Data Com. Setup
Parity Bit Even
PS Data Com. Setup
Wait Time 100